SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE
The most common fault in the transmission line is transient fault (70% -90% of the total fault). Most of the disturbances are temporary 1 phase ground disturbances, so SPAR (single pole auto recloser) is used to maintain system stability and continuity. SPAR can fail to work because of the appearanc...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/43579 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:43579 |
---|---|
spelling |
id-itb.:435792019-09-27T14:04:53ZSUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE Trisno Putri, Angellina Indonesia Final Project one phase ground fault, SPAR, secondary arc, resonance INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/43579 The most common fault in the transmission line is transient fault (70% -90% of the total fault). Most of the disturbances are temporary 1 phase ground disturbances, so SPAR (single pole auto recloser) is used to maintain system stability and continuity. SPAR can fail to work because of the appearance of the secondary arc. To reduce secondary arc currents and accelerate arc extinguish time for transposition lines, a Neutral Reactor can be used. From the experimental results, neutral reactor with rated power between 0.2 MVar - 30 MVar can be selected to meet the Java Bali dead time specifications. The selected neutral reactor does not cause resonance. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The most common fault in the transmission line is transient fault (70% -90% of the total fault). Most of the disturbances are temporary 1 phase ground disturbances, so SPAR (single pole auto recloser) is used to maintain system stability and continuity. SPAR can fail to work because of the appearance of the secondary arc. To reduce secondary arc currents and accelerate arc extinguish time for transposition lines, a Neutral Reactor can be used. From the experimental results, neutral reactor with rated power between 0.2 MVar - 30 MVar can be selected to meet the Java Bali dead time specifications. The selected neutral reactor does not cause resonance. |
format |
Final Project |
author |
Trisno Putri, Angellina |
spellingShingle |
Trisno Putri, Angellina SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE |
author_facet |
Trisno Putri, Angellina |
author_sort |
Trisno Putri, Angellina |
title |
SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE |
title_short |
SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE |
title_full |
SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE |
title_fullStr |
SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE |
title_full_unstemmed |
SUPPRESSION OF SECONDARY ARC MODEL WITH NEUTRAL REACTOR FOR SINGLE POLE RECLOSE PURPOSE |
title_sort |
suppression of secondary arc model with neutral reactor for single pole reclose purpose |
url |
https://digilib.itb.ac.id/gdl/view/43579 |
_version_ |
1822926619005681664 |