OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM

Data center is a facility that consume a lot of energy. From total energy used, IT equipment as its major component consume energy by 50%, and cooling system by 37%. There are various strategies to improve the efficiency of the cooling system in order to save energy consumption. Data center opera...

Full description

Saved in:
Bibliographic Details
Main Author: Ridlo Iqbal Mukaffi, Akhmad
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/44916
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:44916
spelling id-itb.:449162019-11-13T10:27:47ZOPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM Ridlo Iqbal Mukaffi, Akhmad Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Final Project Data center, cooling system, energy efficiency,Rack Cooling Index, Power Usage Effectiveness, Computational Fluid Dynamics INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/44916 Data center is a facility that consume a lot of energy. From total energy used, IT equipment as its major component consume energy by 50%, and cooling system by 37%. There are various strategies to improve the efficiency of the cooling system in order to save energy consumption. Data center operates continuously so that the potential of disturbance and shut down due to overheating should be avoided. Optimization is performed by using the Computational Fluid Dynamics (CFD) simulation. Assessment of PAU data center shows that the metric RCI is 100% and the metric PUE is 2,04. The simulation results indicate the presence of mixing between hot air and cold air and cause less efficient of the cooling process. Optimization is carried out by adding blanking panels, cold aisle containment, and changing the layout of the component and shelves. The result show that the value of RCI achieved at 100% for RCIhigh and 99% for RCIlow. Meanwhile, the PUE value is reduced to 1,92. The energy used for cooling system is also reduced by 1,28 kW. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
spellingShingle Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
Ridlo Iqbal Mukaffi, Akhmad
OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM
description Data center is a facility that consume a lot of energy. From total energy used, IT equipment as its major component consume energy by 50%, and cooling system by 37%. There are various strategies to improve the efficiency of the cooling system in order to save energy consumption. Data center operates continuously so that the potential of disturbance and shut down due to overheating should be avoided. Optimization is performed by using the Computational Fluid Dynamics (CFD) simulation. Assessment of PAU data center shows that the metric RCI is 100% and the metric PUE is 2,04. The simulation results indicate the presence of mixing between hot air and cold air and cause less efficient of the cooling process. Optimization is carried out by adding blanking panels, cold aisle containment, and changing the layout of the component and shelves. The result show that the value of RCI achieved at 100% for RCIhigh and 99% for RCIlow. Meanwhile, the PUE value is reduced to 1,92. The energy used for cooling system is also reduced by 1,28 kW.
format Final Project
author Ridlo Iqbal Mukaffi, Akhmad
author_facet Ridlo Iqbal Mukaffi, Akhmad
author_sort Ridlo Iqbal Mukaffi, Akhmad
title OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM
title_short OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM
title_full OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM
title_fullStr OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM
title_full_unstemmed OPTIMIZATION OF PAU ITB DATA CENTER COOLING SYSTEM
title_sort optimization of pau itb data center cooling system
url https://digilib.itb.ac.id/gdl/view/44916
_version_ 1821999236123721728