STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX

STUDY OF REFRIGERANT RETROFIT WITH R-407C TO REPLACE R-22 IN REFRIGERANT PACKAGE UNIT OF NITROGEN PRODUCTION PLANT PT PTX By Muchlish Abdurrohim NIM: 23016021 (Master’s Program in Chemical Enginering) The need for refrigerant replacement in the Refrigerant Package Unit in the process of produc...

Full description

Saved in:
Bibliographic Details
Main Author: Abdurrohim, Muchlish
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/45178
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:45178
spelling id-itb.:451782019-11-26T14:31:03ZSTUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX Abdurrohim, Muchlish Teknik kimia Indonesia Theses Keywords: refrigerant retrofit, refrigerant package, R-22, R-407c, production efficiency, Heat Exchanger. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/45178 STUDY OF REFRIGERANT RETROFIT WITH R-407C TO REPLACE R-22 IN REFRIGERANT PACKAGE UNIT OF NITROGEN PRODUCTION PLANT PT PTX By Muchlish Abdurrohim NIM: 23016021 (Master’s Program in Chemical Enginering) The need for refrigerant replacement in the Refrigerant Package Unit in the process of producing nitrogen gas at PT PTX becomes large because the availability of R-22 refrigerant sources will be stopped due to environmental issues. Replacement of the R-22 refrigerant is carried out retrofitly without replacing the Refractory Package unit. Then it is necessary to study the possibility of using a new refrigerant namely R-407c. So as to ensure that there are no significant changes in operating conditions so that the Nitrogen Gas production unit remains in accordance with its capacity. Increased efficiency can be done by recommending the reuse of energy discharged by exchanging energy using a heat exchanger. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik kimia
spellingShingle Teknik kimia
Abdurrohim, Muchlish
STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX
description STUDY OF REFRIGERANT RETROFIT WITH R-407C TO REPLACE R-22 IN REFRIGERANT PACKAGE UNIT OF NITROGEN PRODUCTION PLANT PT PTX By Muchlish Abdurrohim NIM: 23016021 (Master’s Program in Chemical Enginering) The need for refrigerant replacement in the Refrigerant Package Unit in the process of producing nitrogen gas at PT PTX becomes large because the availability of R-22 refrigerant sources will be stopped due to environmental issues. Replacement of the R-22 refrigerant is carried out retrofitly without replacing the Refractory Package unit. Then it is necessary to study the possibility of using a new refrigerant namely R-407c. So as to ensure that there are no significant changes in operating conditions so that the Nitrogen Gas production unit remains in accordance with its capacity. Increased efficiency can be done by recommending the reuse of energy discharged by exchanging energy using a heat exchanger.
format Theses
author Abdurrohim, Muchlish
author_facet Abdurrohim, Muchlish
author_sort Abdurrohim, Muchlish
title STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX
title_short STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX
title_full STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX
title_fullStr STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX
title_full_unstemmed STUDI REFRIJERAN RETROFIT DENGAN TIPE R-407C UNTUK MENGGANTIKAN R-22 DI UNIT REFRIJERAN PACKAGE PADA PROSES PRODUKSI GAS NITROGEN PT PTX
title_sort studi refrijeran retrofit dengan tipe r-407c untuk menggantikan r-22 di unit refrijeran package pada proses produksi gas nitrogen pt ptx
url https://digilib.itb.ac.id/gdl/view/45178
_version_ 1822927028428472320