FAILURE ANALYSIS ON HEMISPHERICAL HEAD OF S-50 AMMONIA CONVERTER PRESSURE VESSEL IN AMMONIA PLANT

S-50 Ammonia converter is a pressure vessel with a type of radial flow converter where the conversion process from process gas to ammonia occurs at high pressure and temperature using the help of catalysts inside the vessel. From the inspection results, it was found that the crack failure penetrates...

Full description

Saved in:
Bibliographic Details
Main Author: Nugraha Saputra, Irwan
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/46104