ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS

Lupus is an autoimmune disease that causes chronic inflammation. Increases or decreases in blood glucose, uric acid, and cholesterol levels can occur in people with lupus (odapus), so a simple checkup can be done independently (selfmonitoring). In the use of self-monitoring commercial devices ther...

Full description

Saved in:
Bibliographic Details
Main Author: Dwi Rahayu, Ihsanti
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/46354
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:46354
spelling id-itb.:463542020-03-02T15:38:29ZACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS Dwi Rahayu, Ihsanti Indonesia Theses blood glucose, uric acid, cholesterol, lupus, self-monitoring. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/46354 Lupus is an autoimmune disease that causes chronic inflammation. Increases or decreases in blood glucose, uric acid, and cholesterol levels can occur in people with lupus (odapus), so a simple checkup can be done independently (selfmonitoring). In the use of self-monitoring commercial devices there is the possibility of errors and inaccuracies in measurement results. The study aimed was to determine accuracy and precision of 3 brands self-monitoring devices, find out the application of 3 brands self-monitoring devices for measuring blood glucose, uric acid, and cholesterol levels in odapus, and to determine the effect of currently status of the disease and drug use on odapus against the results of measurement from 3 brands self-monitoring commercial devices. Accuracy and precision study were done against 2 different populations namely healthy volunteers and odapus. Accuracy study was conducted by comparing the results of measurement from 3 self-monitoring devices to the clinical laboratory result. The data obtained are then analyzed by paired t test. Precision study was conducted by looking at the significance of difference in the results of measurements for the several times based on the Cronbach’s alpha parameter. Blood glucose, uric acid, and cholesterol levels in odapus were measured using 3 self-monitoring devices that have been tested for accuracy and precision. The results obtained then were compared against healthy volunteers. Based on statistical analysis, the three of self-monitoring devices that were tested proved to be accurate and precise for the measurement of blood glucose and uric acid levels. Whereas the measurement of cholesterol level from the three devices proved to be inaccurate comparing to the clinical laboratory result as standard and 1 device was not precise, proven statistically with Cronbach's alpha value of 0,111. The results of this study indicate that the use of drugs on odapus does not affect the results of measurements of blood glucose, uric acid, and cholesterol levels. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Lupus is an autoimmune disease that causes chronic inflammation. Increases or decreases in blood glucose, uric acid, and cholesterol levels can occur in people with lupus (odapus), so a simple checkup can be done independently (selfmonitoring). In the use of self-monitoring commercial devices there is the possibility of errors and inaccuracies in measurement results. The study aimed was to determine accuracy and precision of 3 brands self-monitoring devices, find out the application of 3 brands self-monitoring devices for measuring blood glucose, uric acid, and cholesterol levels in odapus, and to determine the effect of currently status of the disease and drug use on odapus against the results of measurement from 3 brands self-monitoring commercial devices. Accuracy and precision study were done against 2 different populations namely healthy volunteers and odapus. Accuracy study was conducted by comparing the results of measurement from 3 self-monitoring devices to the clinical laboratory result. The data obtained are then analyzed by paired t test. Precision study was conducted by looking at the significance of difference in the results of measurements for the several times based on the Cronbach’s alpha parameter. Blood glucose, uric acid, and cholesterol levels in odapus were measured using 3 self-monitoring devices that have been tested for accuracy and precision. The results obtained then were compared against healthy volunteers. Based on statistical analysis, the three of self-monitoring devices that were tested proved to be accurate and precise for the measurement of blood glucose and uric acid levels. Whereas the measurement of cholesterol level from the three devices proved to be inaccurate comparing to the clinical laboratory result as standard and 1 device was not precise, proven statistically with Cronbach's alpha value of 0,111. The results of this study indicate that the use of drugs on odapus does not affect the results of measurements of blood glucose, uric acid, and cholesterol levels.
format Theses
author Dwi Rahayu, Ihsanti
spellingShingle Dwi Rahayu, Ihsanti
ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS
author_facet Dwi Rahayu, Ihsanti
author_sort Dwi Rahayu, Ihsanti
title ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS
title_short ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS
title_full ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS
title_fullStr ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS
title_full_unstemmed ACCURACY AND PRECISION STUDY OF SELF-MONITORING COMMERCIAL DEVICES FOR BLOOD GLUCOSE, URIC ACID, AND CHOLESTEROL BLOOD TEST IN LUPUS PATIENTS
title_sort accuracy and precision study of self-monitoring commercial devices for blood glucose, uric acid, and cholesterol blood test in lupus patients
url https://digilib.itb.ac.id/gdl/view/46354
_version_ 1821999577186697216