IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE

This study used computational fluid dynamics (CFD) to analyze the reduction of steam turbine performance due to one-stage rotor removal. A steam turbine which consists of five impulse stages with dry steam as the working fluid are introduced as research model. Three cases that are compared and analy...

Full description

Saved in:
Bibliographic Details
Main Author: Kosasih, Joey
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/47765
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:47765
spelling id-itb.:477652020-06-20T14:42:55ZIMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE Kosasih, Joey Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Final Project steam turbine, computational fluid dynamics, dry steam, rotor removal, power output INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/47765 This study used computational fluid dynamics (CFD) to analyze the reduction of steam turbine performance due to one-stage rotor removal. A steam turbine which consists of five impulse stages with dry steam as the working fluid are introduced as research model. Three cases that are compared and analyzed are operation with full rotor, operation without middle-stage rotor, and operation without last-stage rotor. The steam turbine is modelled using ExportPoints method in ANSYS BladeEditor. Numerical simulations are conducted using the software CFX. The validation process for two cases of rotor removal condition are completed by comparing several parameters with the result of full rotor simulation that is already validated by the actual data from the heat balance diagram of relevant steam turbine. Based on the simulation result, the power output which is produced by the steam turbine operating with full rotor condition has a value of 19.95 MW. Meanwhile, the steam turbine without one-stage rotor produces a fewer amount of power. In the operation without middle-stage rotor case, the power generated are 11.05% less, while in the operation without last-stage rotor case, there is 21.69% power reduction. In additional research concerning one-stage stator and rotor removal, the steam turbine shows a better performance with less power reduction due to components removal. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
spellingShingle Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
Kosasih, Joey
IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE
description This study used computational fluid dynamics (CFD) to analyze the reduction of steam turbine performance due to one-stage rotor removal. A steam turbine which consists of five impulse stages with dry steam as the working fluid are introduced as research model. Three cases that are compared and analyzed are operation with full rotor, operation without middle-stage rotor, and operation without last-stage rotor. The steam turbine is modelled using ExportPoints method in ANSYS BladeEditor. Numerical simulations are conducted using the software CFX. The validation process for two cases of rotor removal condition are completed by comparing several parameters with the result of full rotor simulation that is already validated by the actual data from the heat balance diagram of relevant steam turbine. Based on the simulation result, the power output which is produced by the steam turbine operating with full rotor condition has a value of 19.95 MW. Meanwhile, the steam turbine without one-stage rotor produces a fewer amount of power. In the operation without middle-stage rotor case, the power generated are 11.05% less, while in the operation without last-stage rotor case, there is 21.69% power reduction. In additional research concerning one-stage stator and rotor removal, the steam turbine shows a better performance with less power reduction due to components removal.
format Final Project
author Kosasih, Joey
author_facet Kosasih, Joey
author_sort Kosasih, Joey
title IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE
title_short IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE
title_full IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE
title_fullStr IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE
title_full_unstemmed IMPACT OF ROTOR REMOVAL ON STEAM TURBINE PERFORMANCE
title_sort impact of rotor removal on steam turbine performance
url https://digilib.itb.ac.id/gdl/view/47765
_version_ 1821999939804200960