INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE

With the events related to the energy transition, a shift from a traditional towards a decentralized power generation can be observed. The growing use of volatile, renewable energy sources culminates in the need for storage as well as transportation capabilities in the grids of tomorrow. Transmis...

Full description

Saved in:
Bibliographic Details
Main Author: Surawijaya, Sinanuri
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/47864
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:47864
spelling id-itb.:478642020-06-22T21:47:02ZINVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE Surawijaya, Sinanuri Indonesia Theses MVDC, Overhead Lines, Audible Noise, Flashover Voltage, Insulator INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/47864 With the events related to the energy transition, a shift from a traditional towards a decentralized power generation can be observed. The growing use of volatile, renewable energy sources culminates in the need for storage as well as transportation capabilities in the grids of tomorrow. Transmission and distribution grids worldwide are based on alternating current (AC), a well-established technology. This concept works reliable and stable but comes along with some restrictions. The transmittable power is limited by factors like the need for reactive power, which affects the maximum transmission length. Furthermore, dielectric losses as well as the skin effect limit the efficiency of AC power transmission. Due to these restrictions, the use of Direct Current (DC) can be beneficial. The Medium Voltage Direct Current (MVDC) power transmission is a promising approach to enhance the transport capacity of transmission links, such as cables or overhead lines. As several publications point out, the possibility of converting existing Medium Voltage Alternating Current (MVAC) overhead lines (OHL) to DC operation, the aspect of using overhead lines in such systems has to be investigated. Therefore, locally used MVAC insulators (Austria, Indonesia) as well as conductors are tested in terms of flashover strength and audible noise behaviour under DC voltages. Environmental parameters like moisture, temperature and surface pollution are to be considered. In terms of audible noise, overhead line conductors operated with DC voltage do not significantly affect the increase in audible noise and the value obtained is around 23-30 dB. It is the same as rustling leaves and will not have a significant impact on the surrounding environment. Meanwhile, in terms of flashover voltage, taking into account light pollution, the possibility of DC voltage that can be applied to Austrian overhead lines up to ± 60 kV DC and the transmitted power increases by 408%. Meanwhile, for Indonesian overhead lines up to ± 40 kV DC can be considered and the power transferred can increase by 272%. From a technical point of view, MVAC overhead lines can be converted with DC voltage without replacing existing equipment. Only the addition of converter equipment is needed to convert voltage from AC to DC and vice versa. However, for determining the DC voltage used, knowledge about the geographical location and the resulting pollution as well as further line-specific calculations regarding insulation coordination are required. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description With the events related to the energy transition, a shift from a traditional towards a decentralized power generation can be observed. The growing use of volatile, renewable energy sources culminates in the need for storage as well as transportation capabilities in the grids of tomorrow. Transmission and distribution grids worldwide are based on alternating current (AC), a well-established technology. This concept works reliable and stable but comes along with some restrictions. The transmittable power is limited by factors like the need for reactive power, which affects the maximum transmission length. Furthermore, dielectric losses as well as the skin effect limit the efficiency of AC power transmission. Due to these restrictions, the use of Direct Current (DC) can be beneficial. The Medium Voltage Direct Current (MVDC) power transmission is a promising approach to enhance the transport capacity of transmission links, such as cables or overhead lines. As several publications point out, the possibility of converting existing Medium Voltage Alternating Current (MVAC) overhead lines (OHL) to DC operation, the aspect of using overhead lines in such systems has to be investigated. Therefore, locally used MVAC insulators (Austria, Indonesia) as well as conductors are tested in terms of flashover strength and audible noise behaviour under DC voltages. Environmental parameters like moisture, temperature and surface pollution are to be considered. In terms of audible noise, overhead line conductors operated with DC voltage do not significantly affect the increase in audible noise and the value obtained is around 23-30 dB. It is the same as rustling leaves and will not have a significant impact on the surrounding environment. Meanwhile, in terms of flashover voltage, taking into account light pollution, the possibility of DC voltage that can be applied to Austrian overhead lines up to ± 60 kV DC and the transmitted power increases by 408%. Meanwhile, for Indonesian overhead lines up to ± 40 kV DC can be considered and the power transferred can increase by 272%. From a technical point of view, MVAC overhead lines can be converted with DC voltage without replacing existing equipment. Only the addition of converter equipment is needed to convert voltage from AC to DC and vice versa. However, for determining the DC voltage used, knowledge about the geographical location and the resulting pollution as well as further line-specific calculations regarding insulation coordination are required.
format Theses
author Surawijaya, Sinanuri
spellingShingle Surawijaya, Sinanuri
INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE
author_facet Surawijaya, Sinanuri
author_sort Surawijaya, Sinanuri
title INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE
title_short INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE
title_full INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE
title_fullStr INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE
title_full_unstemmed INVESTIGATION OF THE POSSIBILITY TO CONVERT MEDIUM-VOLTAGE AC OVERHEAD LINES (OHL) TO DC CASE STUDY: INDONESIAN AND AUSTRIAN MVAC OVERHEAD LINE
title_sort investigation of the possibility to convert medium-voltage ac overhead lines (ohl) to dc case study: indonesian and austrian mvac overhead line
url https://digilib.itb.ac.id/gdl/view/47864
_version_ 1822927765794455552