DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION

In general, EMG signal frequencies are in the range of 5 Hz to 128 Hz. In order to properly measure EMG signals, the sampling frequency of used EMG device must be at least 256 Hz. Recently most of the EMG devices could sample EMG signals up to 2048 Hz. Higher sampling frequency of EMG device results...

Full description

Saved in:
Bibliographic Details
Main Author: Amandi R, Rachmat
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/47966
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:47966
spelling id-itb.:479662020-06-24T23:36:36ZDEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION Amandi R, Rachmat Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Final Project electromyography, open hardware, sampling frequency, instrumentation, bio-feedback. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/47966 In general, EMG signal frequencies are in the range of 5 Hz to 128 Hz. In order to properly measure EMG signals, the sampling frequency of used EMG device must be at least 256 Hz. Recently most of the EMG devices could sample EMG signals up to 2048 Hz. Higher sampling frequency of EMG device results in sharper measured EMG signal. However, the computational load required to process the EMG signal will be higher. Currently EMG signals is used for many purposes, including monitoring muscle activities during medical rehabilitation and as control signals for gaming and robotics. The increasing usage of EMG signals has led to the development of open hardware EMG devices. One of the open hardware EMG device with sampling frequency that could reach 256 Hz is OpenBCI Cyton. OpenBCI Cyton main component is a digital bioamplifier that functions as amplifier and ADC with standard sampling frequency of 250 Hz. OpenBCI Cyton sampling frequency can reach up to 1 kHz while connected to OpenBCI WiFi Shield. The main purpose of this research is to design open hardware-based wireless EMG device. Sampling frequency test for OpenBCI WiFi Shield resulting in a maximum effective sampling frequency of 500 Hz. OpenBCI WiFi Shield configuration resulting in higher background noise amplitude than the standard configuration, which are 11,811 mV and 4,088 mV respectively. Power spectrum analysis shows that the standard configuration resulting in sharper decline of signal power above 60 Hz. The use of OpenBCI WiFi Shield successfully reduce the aliasing effect due to undersampling, with the disadvantage of higher background noise amplitude. Statistical analysis shows that differences in sampling frequency resulting in a significant difference on the EMG signal. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
spellingShingle Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
Amandi R, Rachmat
DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION
description In general, EMG signal frequencies are in the range of 5 Hz to 128 Hz. In order to properly measure EMG signals, the sampling frequency of used EMG device must be at least 256 Hz. Recently most of the EMG devices could sample EMG signals up to 2048 Hz. Higher sampling frequency of EMG device results in sharper measured EMG signal. However, the computational load required to process the EMG signal will be higher. Currently EMG signals is used for many purposes, including monitoring muscle activities during medical rehabilitation and as control signals for gaming and robotics. The increasing usage of EMG signals has led to the development of open hardware EMG devices. One of the open hardware EMG device with sampling frequency that could reach 256 Hz is OpenBCI Cyton. OpenBCI Cyton main component is a digital bioamplifier that functions as amplifier and ADC with standard sampling frequency of 250 Hz. OpenBCI Cyton sampling frequency can reach up to 1 kHz while connected to OpenBCI WiFi Shield. The main purpose of this research is to design open hardware-based wireless EMG device. Sampling frequency test for OpenBCI WiFi Shield resulting in a maximum effective sampling frequency of 500 Hz. OpenBCI WiFi Shield configuration resulting in higher background noise amplitude than the standard configuration, which are 11,811 mV and 4,088 mV respectively. Power spectrum analysis shows that the standard configuration resulting in sharper decline of signal power above 60 Hz. The use of OpenBCI WiFi Shield successfully reduce the aliasing effect due to undersampling, with the disadvantage of higher background noise amplitude. Statistical analysis shows that differences in sampling frequency resulting in a significant difference on the EMG signal.
format Final Project
author Amandi R, Rachmat
author_facet Amandi R, Rachmat
author_sort Amandi R, Rachmat
title DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION
title_short DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION
title_full DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION
title_fullStr DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION
title_full_unstemmed DEVELOPMENT OF OPEN HARDWARE-BASED WIRELESS ELECTROMYOGRAPHY (EMG) SYSTEM FOR BIO-FEEDBACK DURING MUSCLE ACTIVITY QUANTIFICATION
title_sort development of open hardware-based wireless electromyography (emg) system for bio-feedback during muscle activity quantification
url https://digilib.itb.ac.id/gdl/view/47966
_version_ 1821999990015262720