PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT

<b>Abstract :</b><p align="justify"> <br /> Electroosmosis test on kaolinite are conducted with using four concentration levels of NaCl. The concentrations are 0 M (destilated water); 0.001 M; 0.01 M; and 0.1 M. Results of electroosmosis represent that electrokinet...

Full description

Saved in:
Bibliographic Details
Main Author: Semuel Erari (NIM : 20297501), Ishak
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/4800
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:4800
spelling id-itb.:48002006-08-08T07:46:55ZPENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT Semuel Erari (NIM : 20297501), Ishak Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/4800 <b>Abstract :</b><p align="justify"> <br /> Electroosmosis test on kaolinite are conducted with using four concentration levels of NaCl. The concentrations are 0 M (destilated water); 0.001 M; 0.01 M; and 0.1 M. Results of electroosmosis represent that electrokinetic potential, flow rate, total dehidrated fluid, coefficient of electroosmotic permeability increase with increasing concentration of NaCL. All position of shear plane are out of the double layer thickness. This position is closer to the surface of particle with higher concentration of NaCl. Transport efficiency increase up to 0.01 M, and lowest transport efficiency is 0.1 M NaCl. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <b>Abstract :</b><p align="justify"> <br /> Electroosmosis test on kaolinite are conducted with using four concentration levels of NaCl. The concentrations are 0 M (destilated water); 0.001 M; 0.01 M; and 0.1 M. Results of electroosmosis represent that electrokinetic potential, flow rate, total dehidrated fluid, coefficient of electroosmotic permeability increase with increasing concentration of NaCL. All position of shear plane are out of the double layer thickness. This position is closer to the surface of particle with higher concentration of NaCl. Transport efficiency increase up to 0.01 M, and lowest transport efficiency is 0.1 M NaCl.
format Theses
author Semuel Erari (NIM : 20297501), Ishak
spellingShingle Semuel Erari (NIM : 20297501), Ishak
PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT
author_facet Semuel Erari (NIM : 20297501), Ishak
author_sort Semuel Erari (NIM : 20297501), Ishak
title PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT
title_short PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT
title_full PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT
title_fullStr PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT
title_full_unstemmed PENGARUH KONSENTRASI NACL TERHADAP ELEKTROOSMOSIS KAOLINIT
title_sort pengaruh konsentrasi nacl terhadap elektroosmosis kaolinit
url https://digilib.itb.ac.id/gdl/view/4800
_version_ 1822014895575531520