UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI
<b>Abstract :</b><p align=\"justify\"> <br /> <br /> <br /> Wet Air Oxidation (WAO) is one of chemical wastewater treatment methods using oxidation process in liquid phase. The purpose of this experiment is studying performance and kinetic of WAO in...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/4906 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:4906 |
---|---|
spelling |
id-itb.:49062006-06-05T18:22:44ZUNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI Setyo Pertiwi, Dyah Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/4906 <b>Abstract :</b><p align=\"justify\"> <br /> <br /> <br /> Wet Air Oxidation (WAO) is one of chemical wastewater treatment methods using oxidation process in liquid phase. The purpose of this experiment is studying performance and kinetic of WAO in treating high COD wastewater.<p align=\"justify\"> <br /> <br /> <br /> Wine and spiritus industry wastewater is used in this experiment. The equipment used is a stirred autoclave with an automatic control. The experiment includes batch and semi batch operations. The batch operation is pretreatment for the wastewater, conducted in 55 bars, 2 hours, and oxygen-free. The semi batch operation processes batch operation output. Its variables are temperature (150-250°C), compressed air pressure (10-20 bars), and operation duration (0-60 minutes). The analyses include solid, liquid, and gas phase analysis.<p align=\"justify\"> <br /> <br /> <br /> The result are performance parameters as COD reduction and fuel value, and kinetic parameters as Li et. al. (1991) rate constants and point selectivity. The COD reduction in pretreatment operation is 47%. COD reduction in semi batch operations is about 8-40%. It means that the operations produce about 1.6-18.7 Btu/gal.min. k1 and k2 rate constants are about 0.007-2.173/min, and k3 rate constant is about 10\'9-10-8/min. Point selectivity value is about 1.5-7.5. It means that the reaction is selective in producing carboxylic acid than end product of oxidation.<p align=\"justify\"> <br /> <br /> text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik (Rekayasa, enjinering dan kegiatan berkaitan) |
spellingShingle |
Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Setyo Pertiwi, Dyah UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI |
description |
<b>Abstract :</b><p align=\"justify\"> <br />
<br />
<br />
Wet Air Oxidation (WAO) is one of chemical wastewater treatment methods using oxidation process in liquid phase. The purpose of this experiment is studying performance and kinetic of WAO in treating high COD wastewater.<p align=\"justify\"> <br />
<br />
<br />
Wine and spiritus industry wastewater is used in this experiment. The equipment used is a stirred autoclave with an automatic control. The experiment includes batch and semi batch operations. The batch operation is pretreatment for the wastewater, conducted in 55 bars, 2 hours, and oxygen-free. The semi batch operation processes batch operation output. Its variables are temperature (150-250°C), compressed air pressure (10-20 bars), and operation duration (0-60 minutes). The analyses include solid, liquid, and gas phase analysis.<p align=\"justify\"> <br />
<br />
<br />
The result are performance parameters as COD reduction and fuel value, and kinetic parameters as Li et. al. (1991) rate constants and point selectivity. The COD reduction in pretreatment operation is 47%. COD reduction in semi batch operations is about 8-40%. It means that the operations produce about 1.6-18.7 Btu/gal.min. k1 and k2 rate constants are about 0.007-2.173/min, and k3 rate constant is about 10\'9-10-8/min. Point selectivity value is about 1.5-7.5. It means that the reaction is selective in producing carboxylic acid than end product of oxidation.<p align=\"justify\"> <br />
<br />
|
format |
Theses |
author |
Setyo Pertiwi, Dyah |
author_facet |
Setyo Pertiwi, Dyah |
author_sort |
Setyo Pertiwi, Dyah |
title |
UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI |
title_short |
UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI |
title_full |
UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI |
title_fullStr |
UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI |
title_full_unstemmed |
UNTUK MENGOLAH LIMBAH CAIR ORGANIK BERKADAR COD TINGGI |
title_sort |
untuk mengolah limbah cair organik berkadar cod tinggi |
url |
https://digilib.itb.ac.id/gdl/view/4906 |
_version_ |
1820663531033329664 |