OPTIMUM LOCATION ANALYSIS OF STORY ISOLATION SYSTEM ON HIGH RISE BUILDING

Various studies have been carried out to understand the feasibility and mechanisms of the story isolation system. The results obtained are also quite interesting, the use of the story isolation system results in better story drift reduction than the base isolation system. However, these studies only...

Full description

Saved in:
Bibliographic Details
Main Author: Muhammad Reza, Alif
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/49107
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:49107
spelling id-itb.:491072020-09-04T23:11:30ZOPTIMUM LOCATION ANALYSIS OF STORY ISOLATION SYSTEM ON HIGH RISE BUILDING Muhammad Reza, Alif Teknik sipil Indonesia Theses story isolation system, story isolator optimum location, high-rise building INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/49107 Various studies have been carried out to understand the feasibility and mechanisms of the story isolation system. The results obtained are also quite interesting, the use of the story isolation system results in better story drift reduction than the base isolation system. However, these studies only focused on low-rise buildings, even though the story isolation system will be more attractive if it can also be used in high-rise buildings. In this study, numerical analysis was carried out on 30-, 40-, 50-, and 60-story buildings to find the location of the story isolator which resulted in the highest reduction of story drift and story shear. Then a general solution is sought so that it can become a reference for buildings with different plans and height. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
Muhammad Reza, Alif
OPTIMUM LOCATION ANALYSIS OF STORY ISOLATION SYSTEM ON HIGH RISE BUILDING
description Various studies have been carried out to understand the feasibility and mechanisms of the story isolation system. The results obtained are also quite interesting, the use of the story isolation system results in better story drift reduction than the base isolation system. However, these studies only focused on low-rise buildings, even though the story isolation system will be more attractive if it can also be used in high-rise buildings. In this study, numerical analysis was carried out on 30-, 40-, 50-, and 60-story buildings to find the location of the story isolator which resulted in the highest reduction of story drift and story shear. Then a general solution is sought so that it can become a reference for buildings with different plans and height.
format Theses
author Muhammad Reza, Alif
author_facet Muhammad Reza, Alif
author_sort Muhammad Reza, Alif
title OPTIMUM LOCATION ANALYSIS OF STORY ISOLATION SYSTEM ON HIGH RISE BUILDING
title_short OPTIMUM LOCATION ANALYSIS OF STORY ISOLATION SYSTEM ON HIGH RISE BUILDING
title_full OPTIMUM LOCATION ANALYSIS OF STORY ISOLATION SYSTEM ON HIGH RISE BUILDING