DETERMINATION OF WATER TABLE USING 2D GEOELECTRIC METHOD OF DIPOLE-DIPOLE CONFIGURATION AT SIAK REGENCY RIAU PROVINCE
geoelectric method and inversion of data with the topography and interpretation related to the position of water table. The background of this research is because the water table these days plays an important role to fulfill water needs in daily life. This water table is closely related to the ch...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/49114 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | geoelectric method and inversion of data with the topography and interpretation
related to the position of water table. The background of this research is because
the water table these days plays an important role to fulfill water needs in daily life.
This water table is closely related to the characteristics of the rock layers which can
act as aquifers. Water table can be detected by the geoelectrical method because it
is conductive and allows an electric current to flow to the ground so that it can be
used to identify the presence of subsurface water. The method used is 2D
geoelectric method with dipole-dipole configuration and the tool is syscal
multichannel system made by French IRIS with 48 electrodes used. The length of
the track is 950 meters and the spacing of each electrode is 10 meters measured in
Rantau Bertuah Village, Minas sub-district, Siak Regency, Riau. Due to electrode
limitations, overlapping is performed to adjust the length of the path. Based on 2D
geoelectric measurements and interpretation using resistivity values and data
processing using Res2DINV software, it is known that the position of the aquifer
in Siak Regency, Riau is at a depth of approximately 0.5-10 meters along a
trajectory of around 200-300 meters with a resistivity value of between 10-30 ?m
with a water table position at a depth of about 0.5 meters. Then at a depth of
approximately 1-5 meters along a trajectory of about 870-925 meters there is an
aquifer with a resistivity value between 300-700 ?m with a water table position at
a depth of about 1 meter. The two aquifers which are in the range of about 200-300
meters and the trajectories around 870-925 meters are included in the unconfined
aquifer or free aquifer. This aquifer is located closer to the surface, and the water
table position is shallow. |
---|