SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE
Diabetes mellitus (DM) is a chronic disease of metabolic disorder due to the pancreas not producing enough insulin or the body can not use insulin produced effectively. (Indonesian Ministry of Health data and information center, 2014). Monitoring the metabolic status of patients with diabetes mel...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/49506 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:49506 |
---|---|
spelling |
id-itb.:495062020-09-16T20:52:20ZSIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE Ayu Permatasari, Indah Indonesia Final Project Diabetes Mellitus, HbA1c, Non-invasive, Simulation, Digital Filter INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/49506 Diabetes mellitus (DM) is a chronic disease of metabolic disorder due to the pancreas not producing enough insulin or the body can not use insulin produced effectively. (Indonesian Ministry of Health data and information center, 2014). Monitoring the metabolic status of patients with diabetes mellitus is an important part of its management. This monitoring can be done by checking blood glucose or HbA1c. HbA1c levels are tested to show average blood glucose levels for 8-12 weeks. Tests of HbA1c levels is commonly done in an invasive way. This method is done by doing a blood test in the laboratory. Test in the laboratory provides accurate results but requires a long time and must be expensive. Therefore, this final year project focuses on the development of a device that can detect HbA1c levels non-invasively by using the spectroscopy method. On the HbA1c monitoring device there is a digital signal processing sub-system. The sub-system include analog-to-digital conversion and digital filter. IIR (Infinite Impulse Response) and DEMA (Double Exponential Moving Average) is used to reduce noise from PPG signal. Due to limitations caused by the COVID-19 pandemic, the implementation and testing for this final year project is still in the form of circuit simulation. Further work need to be done for physical realization and testing of the design. Simulations are performed to test the filters that have been designed. Synthetic data which is obtained from the modification of the reference dataset is used as an input filter. The performance of the proposed method is evaluated by SNR (Signalto-Noise Ratio). The experimental result shows that the proposed digital filter can increase SNR value of signal around 5-30 dB for noise frequency below 0.5 Hz and above 5 Hz. The evalution show that the proposed digital filter is effective for reducing noise. The maximum value and a minimum value of PPG signal are determined after a clean signal is obtained. The values are sent to an Androidbased smartphone using bluetooth communication. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Diabetes mellitus (DM) is a chronic disease of metabolic disorder due to the
pancreas not producing enough insulin or the body can not use insulin produced
effectively. (Indonesian Ministry of Health data and information center, 2014).
Monitoring the metabolic status of patients with diabetes mellitus is an important
part of its management. This monitoring can be done by checking blood glucose
or HbA1c. HbA1c levels are tested to show average blood glucose levels for 8-12
weeks. Tests of HbA1c levels is commonly done in an invasive way. This method is
done by doing a blood test in the laboratory. Test in the laboratory provides
accurate results but requires a long time and must be expensive. Therefore, this
final year project focuses on the development of a device that can detect HbA1c
levels non-invasively by using the spectroscopy method. On the HbA1c monitoring
device there is a digital signal processing sub-system. The sub-system include
analog-to-digital conversion and digital filter. IIR (Infinite Impulse Response) and
DEMA (Double Exponential Moving Average) is used to reduce noise from PPG
signal.
Due to limitations caused by the COVID-19 pandemic, the implementation and
testing for this final year project is still in the form of circuit simulation. Further
work need to be done for physical realization and testing of the design.
Simulations are performed to test the filters that have been designed. Synthetic
data which is obtained from the modification of the reference dataset is used as an
input filter. The performance of the proposed method is evaluated by SNR (Signalto-Noise Ratio). The experimental result shows that the proposed digital filter can
increase SNR value of signal around 5-30 dB for noise frequency below 0.5 Hz
and above 5 Hz. The evalution show that the proposed digital filter is effective for
reducing noise. The maximum value and a minimum value of PPG signal are
determined after a clean signal is obtained. The values are sent to an Androidbased smartphone using bluetooth communication.
|
format |
Final Project |
author |
Ayu Permatasari, Indah |
spellingShingle |
Ayu Permatasari, Indah SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE |
author_facet |
Ayu Permatasari, Indah |
author_sort |
Ayu Permatasari, Indah |
title |
SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE |
title_short |
SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE |
title_full |
SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE |
title_fullStr |
SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE |
title_full_unstemmed |
SIMULATION OF DIGITAL SIGNAL PROCESSING FOR NON-INVASIVE HBA1C MONITORING DEVICE |
title_sort |
simulation of digital signal processing for non-invasive hba1c monitoring device |
url |
https://digilib.itb.ac.id/gdl/view/49506 |
_version_ |
1822000400484532224 |