SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER

The usage of air conditioner in Indonesia is increasing anually. As a result, national electricity consumption rises because the electric consumption of air conditioner is high. To optimize the usage of electricity, Indonesian Ministry of Energy and Mineral Resources established standard energy e...

Full description

Saved in:
Bibliographic Details
Main Author: Barari, Fajar
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/50408
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:50408
spelling id-itb.:504082020-09-23T22:04:19ZSIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER Barari, Fajar Indonesia Final Project air conditioner, energy efficiency standard, psychrometric chamber. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/50408 The usage of air conditioner in Indonesia is increasing anually. As a result, national electricity consumption rises because the electric consumption of air conditioner is high. To optimize the usage of electricity, Indonesian Ministry of Energy and Mineral Resources established standard energy efficient of air conditioner that regulated in Indonesian Ministry of Energy and Mineral Resources Regulation No. 57 of 2017. However, the numbers of psychrometric chamber which is used as testing facility is too few. Therefore, simulation of pyschrometric chamber is needed to eximine the design of psychrometric chamber. The purpose of this simulation is to obtain the prediction of psychrometric chamber’s characteristic and its duration to attain standard operation based on ISO 5151. Variation of parameters are simulated to observe effect of changes in conductivity, width of insulation and surrounding temperature toward power of compressor and heater to maintain desired conditions. Psychrometric chamber is modeled by mass balance and energy balance equations in transient state. This simulation is done by using Simulink. Operation condition based on ISO 5151 is achieved in 33 minutes, indoor TDB and TWB are 26.8 oC and 19.3 oC while outdoor TDB and TWB are 34.9 oC and 24.0 oC. Decreasing 1 cm of width of insulation resulting addition power of indoor compressor and outdoor heater of 2.46 W (0.05%) and 12.69 W (0.29%). Increasing 0.0062 W/m.K of thermal conductivity resulting addition power of indoor compressor and outdoor heater of 2.22 W (0.05%) and 11.42 W (0.27%). Increasing 2 oC of surrounding temperature resulting addition indoor compressor power of 19.5 W (0.44%) while reduction outdoor heater power of 45.53 W (1.07%). text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The usage of air conditioner in Indonesia is increasing anually. As a result, national electricity consumption rises because the electric consumption of air conditioner is high. To optimize the usage of electricity, Indonesian Ministry of Energy and Mineral Resources established standard energy efficient of air conditioner that regulated in Indonesian Ministry of Energy and Mineral Resources Regulation No. 57 of 2017. However, the numbers of psychrometric chamber which is used as testing facility is too few. Therefore, simulation of pyschrometric chamber is needed to eximine the design of psychrometric chamber. The purpose of this simulation is to obtain the prediction of psychrometric chamber’s characteristic and its duration to attain standard operation based on ISO 5151. Variation of parameters are simulated to observe effect of changes in conductivity, width of insulation and surrounding temperature toward power of compressor and heater to maintain desired conditions. Psychrometric chamber is modeled by mass balance and energy balance equations in transient state. This simulation is done by using Simulink. Operation condition based on ISO 5151 is achieved in 33 minutes, indoor TDB and TWB are 26.8 oC and 19.3 oC while outdoor TDB and TWB are 34.9 oC and 24.0 oC. Decreasing 1 cm of width of insulation resulting addition power of indoor compressor and outdoor heater of 2.46 W (0.05%) and 12.69 W (0.29%). Increasing 0.0062 W/m.K of thermal conductivity resulting addition power of indoor compressor and outdoor heater of 2.22 W (0.05%) and 11.42 W (0.27%). Increasing 2 oC of surrounding temperature resulting addition indoor compressor power of 19.5 W (0.44%) while reduction outdoor heater power of 45.53 W (1.07%).
format Final Project
author Barari, Fajar
spellingShingle Barari, Fajar
SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER
author_facet Barari, Fajar
author_sort Barari, Fajar
title SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER
title_short SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER
title_full SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER
title_fullStr SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER
title_full_unstemmed SIMULATION OF PSYCHROMETRIC CHAMBER FOR RESIDENTIAL AIR CONDITIONER
title_sort simulation of psychrometric chamber for residential air conditioner
url https://digilib.itb.ac.id/gdl/view/50408
_version_ 1822000651201150976