APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS

Dead-time is necessary in a PWM inverter to avoid short-corcuiting the DC source through the semiconductor switches. Due to the momentary loss of voltage control during dead-time, the output voltage becomes distorted, particularly with low-order harmonics. In motor applications, current harmonics...

Full description

Saved in:
Bibliographic Details
Main Author: Ardriani, Tri
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/50605
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:50605
spelling id-itb.:506052020-09-24T20:03:12ZAPPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS Ardriani, Tri Indonesia Theses PWM inverter, current ripple, virtual impedance, current controller, dead-time effect INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/50605 Dead-time is necessary in a PWM inverter to avoid short-corcuiting the DC source through the semiconductor switches. Due to the momentary loss of voltage control during dead-time, the output voltage becomes distorted, particularly with low-order harmonics. In motor applications, current harmonics may increase losses, heating, and cause torque pulsation. Low-order harmonics are difficult to suppress using conventional filters. Therefore, a special mitigation strategy is required. Dead-time mitigation methods are generally grouped into two categories: feedforward and feedback methods. In feedforward method, the reference is changed according to a preconceived model of the disturbance. This method requires accurate modeling, hence difficult to implement as dead-time effect always varies with load conditions. Feedback method is simpler. However, to suppress low-frequency disturbance, a high feedback gain is needed, which may jeopardize the system’s stability. A resonant controller has infinite gain at the resonant frequency and may work well to suppress certain harmonics. Its drawback is that it rapidly turns complex as more frequencies are being targeted. Moreover, it is not suitable for variable frequency applications. In this research, a control method based on virtual impedance concept is proposed to suppress dead-time effect. Virtual impedance is a controller block that mimics the behavior of a real impedance. Because it is virtual, it can be designed only to affect the disturbance signals. It may have unique characteristics that cannot be realized with real impedance. It can also be added as a plug-in to an already existing controller. The validity of the proposed method is verified through simulation and experiment. Several combinations of virtual impedance, as well as its extended design as a virtual filter, are compared with respect to their abilities in reducing THD levels. Lastly, experimental results are provided, showcasing the effectiveness of a virtual impedance in improving a current controllers’s performance. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Dead-time is necessary in a PWM inverter to avoid short-corcuiting the DC source through the semiconductor switches. Due to the momentary loss of voltage control during dead-time, the output voltage becomes distorted, particularly with low-order harmonics. In motor applications, current harmonics may increase losses, heating, and cause torque pulsation. Low-order harmonics are difficult to suppress using conventional filters. Therefore, a special mitigation strategy is required. Dead-time mitigation methods are generally grouped into two categories: feedforward and feedback methods. In feedforward method, the reference is changed according to a preconceived model of the disturbance. This method requires accurate modeling, hence difficult to implement as dead-time effect always varies with load conditions. Feedback method is simpler. However, to suppress low-frequency disturbance, a high feedback gain is needed, which may jeopardize the system’s stability. A resonant controller has infinite gain at the resonant frequency and may work well to suppress certain harmonics. Its drawback is that it rapidly turns complex as more frequencies are being targeted. Moreover, it is not suitable for variable frequency applications. In this research, a control method based on virtual impedance concept is proposed to suppress dead-time effect. Virtual impedance is a controller block that mimics the behavior of a real impedance. Because it is virtual, it can be designed only to affect the disturbance signals. It may have unique characteristics that cannot be realized with real impedance. It can also be added as a plug-in to an already existing controller. The validity of the proposed method is verified through simulation and experiment. Several combinations of virtual impedance, as well as its extended design as a virtual filter, are compared with respect to their abilities in reducing THD levels. Lastly, experimental results are provided, showcasing the effectiveness of a virtual impedance in improving a current controllers’s performance.
format Theses
author Ardriani, Tri
spellingShingle Ardriani, Tri
APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS
author_facet Ardriani, Tri
author_sort Ardriani, Tri
title APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS
title_short APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS
title_full APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS
title_fullStr APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS
title_full_unstemmed APPLICATION OF VIRTUAL IMPEDANCE TO SUPPRESS DEAD-TIME EFFECT IN CURRENT-CONTROLLED PWM INVERTERS
title_sort application of virtual impedance to suppress dead-time effect in current-controlled pwm inverters
url https://digilib.itb.ac.id/gdl/view/50605
_version_ 1822928499035340800