RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT
In a humidity sensor development, the sensor testing stage is an evaluation stage as well as a stage for observing the characteristics of the sensor being developed. However, in the ITB laboratory, there are still deficiencies in the test method, namely in terms of time efficiency and limitations...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/50965 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:50965 |
---|---|
spelling |
id-itb.:509652020-09-25T21:05:40ZRELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT Abror Pramudyana, Rauf Indonesia Final Project Humidifier, Dehumidifier, Humidity, Data Acquisition, Resistive. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/50965 In a humidity sensor development, the sensor testing stage is an evaluation stage as well as a stage for observing the characteristics of the sensor being developed. However, in the ITB laboratory, there are still deficiencies in the test method, namely in terms of time efficiency and limitations for conducting temperature conditioning. Therefore, a device was designed that could manipulate the humidity and temperature of the test room according to the test requirements in less time than the previous method. The subject matter in this document is the humidifier subsystem, dehumidifier, and data acquisition on resistive test sensors that are part of the overall system builder. Humidifier and dehumidifier subsystems work with a humidity control system that uses if conditions to regulate the on and off conditions of the subsystems. Data acquisition on the resistive test sensor is done by measuring the output voltage value of the Wheatstone bridge circuit which converts the test sensor resistance value into a voltage value. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
In a humidity sensor development, the sensor testing stage is an evaluation stage
as well as a stage for observing the characteristics of the sensor being developed.
However, in the ITB laboratory, there are still deficiencies in the test method,
namely in terms of time efficiency and limitations for conducting temperature
conditioning. Therefore, a device was designed that could manipulate the humidity
and temperature of the test room according to the test requirements in less time
than the previous method. The subject matter in this document is the humidifier
subsystem, dehumidifier, and data acquisition on resistive test sensors that are part
of the overall system builder. Humidifier and dehumidifier subsystems work with a
humidity control system that uses if conditions to regulate the on and off conditions
of the subsystems. Data acquisition on the resistive test sensor is done by measuring
the output voltage value of the Wheatstone bridge circuit which converts the test
sensor resistance value into a voltage value. |
format |
Final Project |
author |
Abror Pramudyana, Rauf |
spellingShingle |
Abror Pramudyana, Rauf RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT |
author_facet |
Abror Pramudyana, Rauf |
author_sort |
Abror Pramudyana, Rauf |
title |
RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT |
title_short |
RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT |
title_full |
RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT |
title_fullStr |
RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT |
title_full_unstemmed |
RELATIVE HUMIDITY CONTROL SYSTEM AND RESISTIVE SENSOR DATA ACQUISITION IN AIR HUMIDITY SENSOR TEST CHAMBER AGAINST CHANGES IN RELATIVE HUMIDITY (RH) OF AIR AT SEVERAL TEMPERATURE SET POINT |
title_sort |
relative humidity control system and resistive sensor data acquisition in air humidity sensor test chamber against changes in relative humidity (rh) of air at several temperature set point |
url |
https://digilib.itb.ac.id/gdl/view/50965 |
_version_ |
1822928601731825664 |