EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS

Along with the development of technology, interest in the utilization of micro-fluid channels (micro-channel) is increasing. Fluid flow will not be separated from flow losses, especially when the fluid passes through bends and friction on the channel wall surface. The purpose of this study was to...

Full description

Saved in:
Bibliographic Details
Main Author: Junianto, Endro
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/53277
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:53277
spelling id-itb.:532772021-03-03T11:07:05ZEXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS Junianto, Endro Indonesia Theses microchannel, loss coefficient, pressure drop. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/53277 Along with the development of technology, interest in the utilization of micro-fluid channels (micro-channel) is increasing. Fluid flow will not be separated from flow losses, especially when the fluid passes through bends and friction on the channel wall surface. The purpose of this study was to determine the value of the loss coefficient and the value of pressure drop due to changes in the aspects of the cross-sectional diameter, angle of bending, and the Reynolds number value in the micro-channel. The research method used is an experimental method which is carried out in the laboratory by observing the research parameters in the form of water and kerosene flow that is passed through the micro-channel bends with varying angle of bending 45o, 60o, 90o, 120o, and 135o and varied cross-sectional diameter of 348 ?m, 1204 ?m, and 1860 ?m and the Reynolds number. The Reynolds number range in this test is 60–7905. The test results show that the pressure drop increases and the bends loss coefficient decrease with increasing Reynolds number at each variation of the bending angle. An increase in the angle of bends and a decrease in the cross-sectional diameter at the same Reynolds number causes an increased pressure drop. The bends loss coefficient decreases with the increase in the magnitude of the angle of bends and the reduction in the cross-sectional diameter at the same Reynolds number. The test channel at a bending angle of 90o has a bends loss coefficient above 0.9. The pressure drop per unit length increased from 0.04–13 kPa as the Reynolds number increased over the range 60–5929. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Along with the development of technology, interest in the utilization of micro-fluid channels (micro-channel) is increasing. Fluid flow will not be separated from flow losses, especially when the fluid passes through bends and friction on the channel wall surface. The purpose of this study was to determine the value of the loss coefficient and the value of pressure drop due to changes in the aspects of the cross-sectional diameter, angle of bending, and the Reynolds number value in the micro-channel. The research method used is an experimental method which is carried out in the laboratory by observing the research parameters in the form of water and kerosene flow that is passed through the micro-channel bends with varying angle of bending 45o, 60o, 90o, 120o, and 135o and varied cross-sectional diameter of 348 ?m, 1204 ?m, and 1860 ?m and the Reynolds number. The Reynolds number range in this test is 60–7905. The test results show that the pressure drop increases and the bends loss coefficient decrease with increasing Reynolds number at each variation of the bending angle. An increase in the angle of bends and a decrease in the cross-sectional diameter at the same Reynolds number causes an increased pressure drop. The bends loss coefficient decreases with the increase in the magnitude of the angle of bends and the reduction in the cross-sectional diameter at the same Reynolds number. The test channel at a bending angle of 90o has a bends loss coefficient above 0.9. The pressure drop per unit length increased from 0.04–13 kPa as the Reynolds number increased over the range 60–5929.
format Theses
author Junianto, Endro
spellingShingle Junianto, Endro
EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS
author_facet Junianto, Endro
author_sort Junianto, Endro
title EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS
title_short EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS
title_full EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS
title_fullStr EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS
title_full_unstemmed EXPERIMENTAL STUDY OF SINGLE PHASE FLUID FLOW LOSS COEFFICIENT IN MICROCHANNEL BENDS
title_sort experimental study of single phase fluid flow loss coefficient in microchannel bends
url https://digilib.itb.ac.id/gdl/view/53277
_version_ 1822273449204121600