STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK

<b>Abstract :</b><p align=\"justify\"> <br /> <br /> If an electrical equipment like power transformers has a modification, maybe the Basic Insulation Level (BIL) of the equipment mentioned will be changed. To decide the new value of the BIL is very complic...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Surya Saputra, Wasimudin
التنسيق: Theses
اللغة:Indonesia
الوصول للمادة أونلاين:https://digilib.itb.ac.id/gdl/view/5350
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
المؤسسة: Institut Teknologi Bandung
اللغة: Indonesia
id id-itb.:5350
spelling id-itb.:53502006-09-25T09:37:25ZSTUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK Surya Saputra, Wasimudin Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/5350 <b>Abstract :</b><p align=\"justify\"> <br /> <br /> If an electrical equipment like power transformers has a modification, maybe the Basic Insulation Level (BIL) of the equipment mentioned will be changed. To decide the new value of the BIL is very complicated.<p align=\"justify\"> <br /> <br /> <br /> According to the IEC Standards, the BIL of an equipment is defined as an insulation strength of equipment against peak value of impulse voltage 1,2/50 ps. However, for the modified power transformers, the Standard is impossible to apply because the impulse test on power transformers is type test. It means that it can be done on the sample and it is considered as the destruction test.<p align=\"justify\"> <br /> <br /> <br /> This paper describes a method to estimate the BIL of power transformers through numeric simulation. For the need mentioned, a pro-rated of single phase transformers is made. This pro-rated consists of high and low voltage winding which has 24 turns each. The numeric model which represented transient conditions of this pro-rated is validated with the result of the impulse voltage application experiment from the hybrid generator 3 kV 1,2/50 ps source. In the hope of getting a numeric model that can be used to evaluate the BIL of this pro-rated and it can he used to the real transformers, the result of experiment and EAITP simulation are compared.<p align=\"justify\"> <br /> <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <b>Abstract :</b><p align=\"justify\"> <br /> <br /> If an electrical equipment like power transformers has a modification, maybe the Basic Insulation Level (BIL) of the equipment mentioned will be changed. To decide the new value of the BIL is very complicated.<p align=\"justify\"> <br /> <br /> <br /> According to the IEC Standards, the BIL of an equipment is defined as an insulation strength of equipment against peak value of impulse voltage 1,2/50 ps. However, for the modified power transformers, the Standard is impossible to apply because the impulse test on power transformers is type test. It means that it can be done on the sample and it is considered as the destruction test.<p align=\"justify\"> <br /> <br /> <br /> This paper describes a method to estimate the BIL of power transformers through numeric simulation. For the need mentioned, a pro-rated of single phase transformers is made. This pro-rated consists of high and low voltage winding which has 24 turns each. The numeric model which represented transient conditions of this pro-rated is validated with the result of the impulse voltage application experiment from the hybrid generator 3 kV 1,2/50 ps source. In the hope of getting a numeric model that can be used to evaluate the BIL of this pro-rated and it can he used to the real transformers, the result of experiment and EAITP simulation are compared.<p align=\"justify\"> <br /> <br />
format Theses
author Surya Saputra, Wasimudin
spellingShingle Surya Saputra, Wasimudin
STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK
author_facet Surya Saputra, Wasimudin
author_sort Surya Saputra, Wasimudin
title STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK
title_short STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK
title_full STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK
title_fullStr STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK
title_full_unstemmed STUDI PENENTUAN TINGKAT ISOLASI DASAR TRANSFORMATOR MELALUI SIMULASI NUMERIK
title_sort studi penentuan tingkat isolasi dasar transformator melalui simulasi numerik
url https://digilib.itb.ac.id/gdl/view/5350
_version_ 1825530833556996096