EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG

<b>Abstract:<p align="justify"> <br /> <br /> <br /> <br /> Stilling basin is building on share downstream weir body that are limited by jetty base weir that function to reduce the energy water as effect damming up in order to water in downstream...

Full description

Saved in:
Bibliographic Details
Main Author: Rasjid, Abd.Rachman
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/5379
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:5379
spelling id-itb.:53792006-01-17T15:31:04ZEVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG Rasjid, Abd.Rachman Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/5379 <b>Abstract:<p align="justify"> <br /> <br /> <br /> <br /> Stilling basin is building on share downstream weir body that are limited by jetty base weir that function to reduce the energy water as effect damming up in order to water in downstream of weir do not bring about local scoring.<p align="justify"> <br /> <br /> <br /> In placing concept using stilling basin on dam, both of new weir and problem weir are needed by made a research with the model test. For design weir hydraulic with stilling basin, approach hydraulic research that are made systematic its final result will be obtained a more accurate fonnula.<p align="justify"> <br /> <br /> <br /> Part of downstream stilling basin Ciherang weir have experienced local scoring, in research test physical model two dimension scale 1 : 30 with stream flow rate of flood period 50 annual result that be obtained as follows: <br /> a. Serial Model 0 <br /> Scoring that happened on downstream stilling basin building as far as more than 30 meters and deepness more than 3,00 meters. <br /> b. Serial Model 1 <br /> Scoring that happened on downstream stilling basin building as far as more than 27 meters with deepness 2.90 meters. <br /> c. Serial Model 2 <br /> Scoring that happened on downstream stilling basin building as far as more than 27 meters with deepness 2.87 meters. <br /> d. Serial Model 3 <br /> Scoring that happened on downstream stilling basin building as far as more than 24 meters with deepness 2,61 meters.<p align="justify"> <br /> <br /> <br /> From result research test model, long scoring happened because by rate of flow flood annual and scoring on foot of stilling basin because by dominant flood that often happen.<p align="justify"> <br /> <br /> <br /> For returning stilling basin building function at Ciherang weir that with condition moment, necessary are made rehabilitate the building with increasing float back part, float of middle and block of face so that water energy that are bring about on building can be reduce, long and deepness scoring will be relative minimize. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <b>Abstract:<p align="justify"> <br /> <br /> <br /> <br /> Stilling basin is building on share downstream weir body that are limited by jetty base weir that function to reduce the energy water as effect damming up in order to water in downstream of weir do not bring about local scoring.<p align="justify"> <br /> <br /> <br /> In placing concept using stilling basin on dam, both of new weir and problem weir are needed by made a research with the model test. For design weir hydraulic with stilling basin, approach hydraulic research that are made systematic its final result will be obtained a more accurate fonnula.<p align="justify"> <br /> <br /> <br /> Part of downstream stilling basin Ciherang weir have experienced local scoring, in research test physical model two dimension scale 1 : 30 with stream flow rate of flood period 50 annual result that be obtained as follows: <br /> a. Serial Model 0 <br /> Scoring that happened on downstream stilling basin building as far as more than 30 meters and deepness more than 3,00 meters. <br /> b. Serial Model 1 <br /> Scoring that happened on downstream stilling basin building as far as more than 27 meters with deepness 2.90 meters. <br /> c. Serial Model 2 <br /> Scoring that happened on downstream stilling basin building as far as more than 27 meters with deepness 2.87 meters. <br /> d. Serial Model 3 <br /> Scoring that happened on downstream stilling basin building as far as more than 24 meters with deepness 2,61 meters.<p align="justify"> <br /> <br /> <br /> From result research test model, long scoring happened because by rate of flow flood annual and scoring on foot of stilling basin because by dominant flood that often happen.<p align="justify"> <br /> <br /> <br /> For returning stilling basin building function at Ciherang weir that with condition moment, necessary are made rehabilitate the building with increasing float back part, float of middle and block of face so that water energy that are bring about on building can be reduce, long and deepness scoring will be relative minimize.
format Theses
author Rasjid, Abd.Rachman
spellingShingle Rasjid, Abd.Rachman
EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG
author_facet Rasjid, Abd.Rachman
author_sort Rasjid, Abd.Rachman
title EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG
title_short EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG
title_full EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG
title_fullStr EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG
title_full_unstemmed EVALUASI DIMENSI RUANG OLAK BENDUNG CIHERANG KABUPATEN BANDUNG
title_sort evaluasi dimensi ruang olak bendung ciherang kabupaten bandung
url https://digilib.itb.ac.id/gdl/view/5379
_version_ 1820663668973502464