ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR

To meet the need for electrical equipment to balance Indonesia's electrification efforts such as the supply of Vacuum Circuit Breakers for medium voltage networks, Indonesia must have local production related to electrical goods such as Vacuum Interrupters in Vacuum Circuit Breakers to incre...

Full description

Saved in:
Bibliographic Details
Main Author: Rifky Santika, Julian
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/54069
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:54069
spelling id-itb.:540692021-03-15T10:17:24ZELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR Rifky Santika, Julian Indonesia Final Project Vacuum Circuit Breaker, Vacuum Interrupter, IEC 62271-100, material, design, region, contactor connection, metallic shield, solid insulator, RMF, gap, contactor, electric field, magnetic field INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/54069 To meet the need for electrical equipment to balance Indonesia's electrification efforts such as the supply of Vacuum Circuit Breakers for medium voltage networks, Indonesia must have local production related to electrical goods such as Vacuum Interrupters in Vacuum Circuit Breakers to increase welfare through increasing TKDN production. In optimizing the TKND value for Vacuum Interrupter, a Vacuum Interrupter design that has been optimized from the existing design is needed and can be produced locally in Indonesia and still meets the VI standard in IEC 62271-100. The VI design requires the most important analysis of the magnetic field and the electric field because according to the VI function it depends on the magnitude of the electric field and the geometry of the magnetic field that is made to resist arching. The electric and magnetic field analysis was carried out on the modeling region VI with the contactor with CuCr material, metallic shield with steel1008 material, and solid insulator with porcelain material. The analysis is performed to simulate the simulation region closer to real, the better with the vacuum space; air; simulation area. The design analysis of the contactor relationship with the fuse between the tip and body is better in terms of the distribution of the electric field. Analysis of the use of metallic shields which is better used in the design because it holds the electric field in a vacuum chamber with solid insulators with floating shielding and polarize shielding types which have similar performance. With a contactor that has an RMF design is better than without fins at all because the spread of the field rotated with 9 fins is better than the total fins below. As well as the minimum gap at the end of the best contactor at 4MV / m of 8.5mm and 10mm gap. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description To meet the need for electrical equipment to balance Indonesia's electrification efforts such as the supply of Vacuum Circuit Breakers for medium voltage networks, Indonesia must have local production related to electrical goods such as Vacuum Interrupters in Vacuum Circuit Breakers to increase welfare through increasing TKDN production. In optimizing the TKND value for Vacuum Interrupter, a Vacuum Interrupter design that has been optimized from the existing design is needed and can be produced locally in Indonesia and still meets the VI standard in IEC 62271-100. The VI design requires the most important analysis of the magnetic field and the electric field because according to the VI function it depends on the magnitude of the electric field and the geometry of the magnetic field that is made to resist arching. The electric and magnetic field analysis was carried out on the modeling region VI with the contactor with CuCr material, metallic shield with steel1008 material, and solid insulator with porcelain material. The analysis is performed to simulate the simulation region closer to real, the better with the vacuum space; air; simulation area. The design analysis of the contactor relationship with the fuse between the tip and body is better in terms of the distribution of the electric field. Analysis of the use of metallic shields which is better used in the design because it holds the electric field in a vacuum chamber with solid insulators with floating shielding and polarize shielding types which have similar performance. With a contactor that has an RMF design is better than without fins at all because the spread of the field rotated with 9 fins is better than the total fins below. As well as the minimum gap at the end of the best contactor at 4MV / m of 8.5mm and 10mm gap.
format Final Project
author Rifky Santika, Julian
spellingShingle Rifky Santika, Julian
ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR
author_facet Rifky Santika, Julian
author_sort Rifky Santika, Julian
title ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR
title_short ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR
title_full ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR
title_fullStr ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR
title_full_unstemmed ELECTRICAL AND MAGNETIC FIELD ANALYSIS ON THE DESIGN OF THE 24KV INTERRUPTER VACUUM CONTACTOR
title_sort electrical and magnetic field analysis on the design of the 24kv interrupter vacuum contactor
url https://digilib.itb.ac.id/gdl/view/54069
_version_ 1822929506162180096