PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING

In the next few years, the amount of global energy consumption is predicted to increase. Indonesia, where the majority of its energy sources come from fossil energy, will be facing an issue about the imbalance between energy supply and demand. To overcome this problem, it can be done to suppre...

Full description

Saved in:
Bibliographic Details
Main Author: Farhan Sidabalok, Muhammad
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/55553
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:55553
spelling id-itb.:555532021-06-18T07:49:28ZPMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING Farhan Sidabalok, Muhammad Indonesia Final Project Energy Consumption, Set-Point, HVAC, PMV INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/55553 In the next few years, the amount of global energy consumption is predicted to increase. Indonesia, where the majority of its energy sources come from fossil energy, will be facing an issue about the imbalance between energy supply and demand. To overcome this problem, it can be done to suppress the amount of energy demand, especially through increasing the efficiency of energy use in the building sector. In this research, a study will be conducted on the impact of the PMV (Predicted Mean Vote)-based HVAC (Heating, Ventilation, and Air Conditioning) system set-point setting method on energy savings potential and peak load curves reductions potential in an office building. The set-point will be changed hourly on a regular basis with the set-point value that can provide the most optimal PMV value. The building being tested will be modeled through the eQuest software which will then be validated using the building's actual daily electrical load profile. From the simulation results using the eQuest software, further data processing will be carried out through the MATLAB software. The results obtained show that setting the set-point per hour on a regular basis based on the optimal PMV value can save the building's HVAC energy consumption for one year by 178.51 kWh or 12.39%. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description In the next few years, the amount of global energy consumption is predicted to increase. Indonesia, where the majority of its energy sources come from fossil energy, will be facing an issue about the imbalance between energy supply and demand. To overcome this problem, it can be done to suppress the amount of energy demand, especially through increasing the efficiency of energy use in the building sector. In this research, a study will be conducted on the impact of the PMV (Predicted Mean Vote)-based HVAC (Heating, Ventilation, and Air Conditioning) system set-point setting method on energy savings potential and peak load curves reductions potential in an office building. The set-point will be changed hourly on a regular basis with the set-point value that can provide the most optimal PMV value. The building being tested will be modeled through the eQuest software which will then be validated using the building's actual daily electrical load profile. From the simulation results using the eQuest software, further data processing will be carried out through the MATLAB software. The results obtained show that setting the set-point per hour on a regular basis based on the optimal PMV value can save the building's HVAC energy consumption for one year by 178.51 kWh or 12.39%.
format Final Project
author Farhan Sidabalok, Muhammad
spellingShingle Farhan Sidabalok, Muhammad
PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING
author_facet Farhan Sidabalok, Muhammad
author_sort Farhan Sidabalok, Muhammad
title PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING
title_short PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING
title_full PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING
title_fullStr PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING
title_full_unstemmed PMV BASED HVAC SET POINT ADJUSTMENTS IMPACT STUDY ON POTENTIAL ENERGY SAVINGS AND LOAD CURVE PEAK REDUCTIONS IN OFFICE BUILDING
title_sort pmv based hvac set point adjustments impact study on potential energy savings and load curve peak reductions in office building
url https://digilib.itb.ac.id/gdl/view/55553
_version_ 1822929932847677440