VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT

A measurement method by injecting impulse current waves has been tested in this study. This method can directly measure the parameters of impulse impedance, inductance, resistance & peak impedance. The results show that the measurement results have a largeenough error and are needed to test the...

Full description

Saved in:
Bibliographic Details
Main Author: Muliawan Hamzah, Ilham
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/55862
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:55862
spelling id-itb.:558622021-06-19T18:26:31ZVERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT Muliawan Hamzah, Ilham Indonesia Final Project Impulse injection, validation, correction factors INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/55862 A measurement method by injecting impulse current waves has been tested in this study. This method can directly measure the parameters of impulse impedance, inductance, resistance & peak impedance. The results show that the measurement results have a largeenough error and are needed to test the correction factor. In this study, the authors have corrected the factor for each wave front variation by comparing the laboratory test results with the original value, then validated by modeling in the Psim software& testing on the DSDC cable. This correction factor can increase the accuracy of the results up to 90% from before. The form of impulse injection with a face wave time of 5.28 ?s with the smallest error proportion of 2,67%. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description A measurement method by injecting impulse current waves has been tested in this study. This method can directly measure the parameters of impulse impedance, inductance, resistance & peak impedance. The results show that the measurement results have a largeenough error and are needed to test the correction factor. In this study, the authors have corrected the factor for each wave front variation by comparing the laboratory test results with the original value, then validated by modeling in the Psim software& testing on the DSDC cable. This correction factor can increase the accuracy of the results up to 90% from before. The form of impulse injection with a face wave time of 5.28 ?s with the smallest error proportion of 2,67%.
format Final Project
author Muliawan Hamzah, Ilham
spellingShingle Muliawan Hamzah, Ilham
VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT
author_facet Muliawan Hamzah, Ilham
author_sort Muliawan Hamzah, Ilham
title VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT
title_short VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT
title_full VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT
title_fullStr VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT
title_full_unstemmed VERIFICATION AND CALIBRATION OF IMPEDANCE MEASURING INSTRUMENT
title_sort verification and calibration of impedance measuring instrument
url https://digilib.itb.ac.id/gdl/view/55862
_version_ 1822274400080101376