<b></i>Abstrak :</b><i><p align="justify"><br />Removing NH<sub>3</sub> and H<sub>2</sub>S in advanced wastewater treatment has been carrying out by physic-chemical operation air stripping packed column. The basic phenomena are di...

Full description

Saved in:
Bibliographic Details
Main Author: Hidayat (NIM 25394007), Antun
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/5762
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:5762
spelling id-itb.:57622007-02-23T09:27:06Z#TITLE_ALTERNATIVE# Hidayat (NIM 25394007), Antun Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/5762 <b></i>Abstrak :</b><i><p align="justify"><br />Removing NH<sub>3</sub> and H<sub>2</sub>S in advanced wastewater treatment has been carrying out by physic-chemical operation air stripping packed column. The basic phenomena are differences between the solute concentration in liquid phases and concentration in equilibrium that the driving forces causing the gas transfer. Overall mass transfer rate constant (K<sub>L</sub>a) determined experimentally at a packed column and packed with Rashig rings. Experiments yields were compared with rate constants predicted by correlation model of Onda.<br /><p align="justify">The efficiency of NH<sub>3</sub> removal would higher in pH base conditions, meanwhile H<sub>2</sub>S removal would higher in pH acid conditions. The air-water ratio had significant values in NH<sub>3</sub> and H<sub>2</sub>S removal and it was showing optimum efficiency point on ratio 200:1 that indicating lower than computed theory from mass-balance. Improvement of NH<sub>3</sub> and H<sub>2</sub>S removal in packed column from column have no packed were evidenced that packed area gave longer contact time (t) between air to water beside of water bubble area (a).<br /><p align="justify">Over-all Mass Transfer Rate Constant - showing of gradient of reaction rate velocity of stripping - obtained from basic design expression Z = HTU x NTU. The values KLa would higher with high of hydraulic loading, longer time contact process and higher stripping factor (S) that showed by air-water ratio. The deviation of K<sub>L</sub>a experiments to prediction with Onda models caused by differences of experiments air-water ratio were lower than model range.<br /><br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <b></i>Abstrak :</b><i><p align="justify"><br />Removing NH<sub>3</sub> and H<sub>2</sub>S in advanced wastewater treatment has been carrying out by physic-chemical operation air stripping packed column. The basic phenomena are differences between the solute concentration in liquid phases and concentration in equilibrium that the driving forces causing the gas transfer. Overall mass transfer rate constant (K<sub>L</sub>a) determined experimentally at a packed column and packed with Rashig rings. Experiments yields were compared with rate constants predicted by correlation model of Onda.<br /><p align="justify">The efficiency of NH<sub>3</sub> removal would higher in pH base conditions, meanwhile H<sub>2</sub>S removal would higher in pH acid conditions. The air-water ratio had significant values in NH<sub>3</sub> and H<sub>2</sub>S removal and it was showing optimum efficiency point on ratio 200:1 that indicating lower than computed theory from mass-balance. Improvement of NH<sub>3</sub> and H<sub>2</sub>S removal in packed column from column have no packed were evidenced that packed area gave longer contact time (t) between air to water beside of water bubble area (a).<br /><p align="justify">Over-all Mass Transfer Rate Constant - showing of gradient of reaction rate velocity of stripping - obtained from basic design expression Z = HTU x NTU. The values KLa would higher with high of hydraulic loading, longer time contact process and higher stripping factor (S) that showed by air-water ratio. The deviation of K<sub>L</sub>a experiments to prediction with Onda models caused by differences of experiments air-water ratio were lower than model range.<br /><br />
format Theses
author Hidayat (NIM 25394007), Antun
spellingShingle Hidayat (NIM 25394007), Antun
#TITLE_ALTERNATIVE#
author_facet Hidayat (NIM 25394007), Antun
author_sort Hidayat (NIM 25394007), Antun
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/5762
_version_ 1820663752585904128