PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA

The project studied in this design thesis is a hotel and convention center building which is planned in Kuningan, Jakarta. The building consists of a tower side and a podium side where the tower side consists of x floors and the podium side consists of y floors, and under both sides are 2 basemen...

Full description

Saved in:
Bibliographic Details
Main Author: Wiranto
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/58111
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:58111
spelling id-itb.:581112021-08-31T09:58:13ZPILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA Wiranto Indonesia Final Project geotechnical engineering, lateral earth pressure, diaphragm wall, ground anchor, foundation, bearing capacity, settlement INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/58111 The project studied in this design thesis is a hotel and convention center building which is planned in Kuningan, Jakarta. The building consists of a tower side and a podium side where the tower side consists of x floors and the podium side consists of y floors, and under both sides are 2 basement floors. From the building, the substructure side related to geotechnical engineering will be designed in this thesis. To realize the basement side of the building, excavation needs to be carried out, where the lateral soil pressure needs to be restrained by a retaining structure in the form of a diaphragm wall with a supporting structure in the form of a ground anchor. Analysis of the retaining structure is based on Rankine's theory of lateral earth pressure in undrained soil conditions, where the overturning moment and the holding moment from lateral earth pressure are compared to obtain the required ground anchor dimensions. The design results obtained are then modeled on the Plaxis 2D software, to obtain results that are difficult to obtain with manual calculations. Besides the retaining structure, a building foundation is also designed to carry the load from the superstructure. The foundation used is a group piles foundation with driven piles. Foundation analysis includes bearing capacity and settlement analysis. The axial bearing capacity is analyzed with manual calculations based on the equations from research results that are often used in Indonesia, while the lateral bearing capacity is analyzed by the Group Pile software. Settlement is estimated by manual calculations, which is then compared with the results from the Plaxis 3D software. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The project studied in this design thesis is a hotel and convention center building which is planned in Kuningan, Jakarta. The building consists of a tower side and a podium side where the tower side consists of x floors and the podium side consists of y floors, and under both sides are 2 basement floors. From the building, the substructure side related to geotechnical engineering will be designed in this thesis. To realize the basement side of the building, excavation needs to be carried out, where the lateral soil pressure needs to be restrained by a retaining structure in the form of a diaphragm wall with a supporting structure in the form of a ground anchor. Analysis of the retaining structure is based on Rankine's theory of lateral earth pressure in undrained soil conditions, where the overturning moment and the holding moment from lateral earth pressure are compared to obtain the required ground anchor dimensions. The design results obtained are then modeled on the Plaxis 2D software, to obtain results that are difficult to obtain with manual calculations. Besides the retaining structure, a building foundation is also designed to carry the load from the superstructure. The foundation used is a group piles foundation with driven piles. Foundation analysis includes bearing capacity and settlement analysis. The axial bearing capacity is analyzed with manual calculations based on the equations from research results that are often used in Indonesia, while the lateral bearing capacity is analyzed by the Group Pile software. Settlement is estimated by manual calculations, which is then compared with the results from the Plaxis 3D software.
format Final Project
author Wiranto
spellingShingle Wiranto
PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA
author_facet Wiranto
author_sort Wiranto
title PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA
title_short PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA
title_full PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA
title_fullStr PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA
title_full_unstemmed PILE FOUNDATION AND EARTH RETAINING STRUCTURE DESIGN OF HOTEL AND CONVENTION CENTER PROJECT AT KUNINGAN, JAKARTA
title_sort pile foundation and earth retaining structure design of hotel and convention center project at kuningan, jakarta
url https://digilib.itb.ac.id/gdl/view/58111
_version_ 1822930667880579072