Currently, the development of business hotels in Indonesia is growing rapidly in line with the increasing business development, especially in the Jakarta area, which is known as the center of the business city in Indonesia. With so many companies developing in the area, business hotels have becom...

Full description

Saved in:
Bibliographic Details
Main Author: Fauzi, Ahmad
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/61313
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
Description
Summary:Currently, the development of business hotels in Indonesia is growing rapidly in line with the increasing business development, especially in the Jakarta area, which is known as the center of the business city in Indonesia. With so many companies developing in the area, business hotels have become quite attractive places for entrepreneurs who can be used for business activities. The 4-Star Business Hotel Project in Slipi is one of the hotel projects designed to accommodate lodging and other services that can facilitate business activities in the Jakarta area. This building has the main function as a commercial area that provides lodging facilities as well as supporting and recreational facilities for business activities with a total height of 61 meters consisting of 13 floors, a rooftop, and 2 basement floors. The hotel building that was built must be able to withstand all existing loads including earthquake loads because the Jakarta area is an earthquake prone area. The design of this multi-storey building uses the applicable standards in Indonesia, namely the Standar Nasional Indonesia which is the reference in structural design, SNI 1726: 2019 for earthquake resistant building design and structural analysis, SNI 1727: 2018 for structural loading standards, and SNI 2847: 2019 for reinforcement design and detailing of structural elements. This building is classified in the Seismic Design Category D according to the soil category and earthquake acceleration data around the building site. So that the earthquake resistance system used is a dual system consisting of a Special Moment Resisting Frame System and a Special Structural Wall System. Structural calculations are done manually with the help of CSi ETABS software for structural modeling, SpColumn for modeling and detailing of column reinforcement and for detailing shear wall reinforcement, and CSi SAFE for detailing plate reinforcement.