ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW

Pressure-Temperature-Spinner (PTS) survey is performed in single-phase vapor geothermal well. In previous analysis, crossflow is identified which is expected because of barrier in the reservoir. PTS data analysis is performed to obtain well quantitative data such as feedzones locations, mass flow,...

Full description

Saved in:
Bibliographic Details
Main Author: Firmannanda, Ganar
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/64267
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:64267
spelling id-itb.:642672022-04-27T14:44:40ZANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW Firmannanda, Ganar Pertambangan dan operasi berkaitan Indonesia Final Project PTS survey, productivity index, reservoir pressure, feedzones. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/64267 Pressure-Temperature-Spinner (PTS) survey is performed in single-phase vapor geothermal well. In previous analysis, crossflow is identified which is expected because of barrier in the reservoir. PTS data analysis is performed to obtain well quantitative data such as feedzones locations, mass flow, and fluid enthalpy. Processed data is response of spinner to cable speed which is converted into fluid flow rate. Wellbore Simulator used to validate and quantifying the data, where this simulator uses the energy balance and the conservation of momentum to predict pressure lost and enthalpy change along a segment of depth with a specific rate and fluid properties. Massflow contribution, enthalpy of the zones and the major feedzone is known by that process. Reservoir pressure and PI can be estimated by the processed data. So that the difference of reservoir pressure profile along the productive zone which indicated the barrier in the reservoir is known from the calculations of reservoir pressure correction. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Pertambangan dan operasi berkaitan
spellingShingle Pertambangan dan operasi berkaitan
Firmannanda, Ganar
ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW
description Pressure-Temperature-Spinner (PTS) survey is performed in single-phase vapor geothermal well. In previous analysis, crossflow is identified which is expected because of barrier in the reservoir. PTS data analysis is performed to obtain well quantitative data such as feedzones locations, mass flow, and fluid enthalpy. Processed data is response of spinner to cable speed which is converted into fluid flow rate. Wellbore Simulator used to validate and quantifying the data, where this simulator uses the energy balance and the conservation of momentum to predict pressure lost and enthalpy change along a segment of depth with a specific rate and fluid properties. Massflow contribution, enthalpy of the zones and the major feedzone is known by that process. Reservoir pressure and PI can be estimated by the processed data. So that the difference of reservoir pressure profile along the productive zone which indicated the barrier in the reservoir is known from the calculations of reservoir pressure correction.
format Final Project
author Firmannanda, Ganar
author_facet Firmannanda, Ganar
author_sort Firmannanda, Ganar
title ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW
title_short ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW
title_full ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW
title_fullStr ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW
title_full_unstemmed ANALISIS DATA SURVEY PRESSURE-TEMPERATURE-SPINNER (PTS) SUMUR PANAS BUMI SATU FASA UAP YANG TERIDENTIFIKASI CROSSFLOW
title_sort analisis data survey pressure-temperature-spinner (pts) sumur panas bumi satu fasa uap yang teridentifikasi crossflow
url https://digilib.itb.ac.id/gdl/view/64267
_version_ 1822004515886333952