PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)

Background and purpose: Ascorbic acid is a compound that relatively unstable to heat, and environmental influences such as light, oxidator and metal ions. The use of ascorbic acid in combination with minerals in pharmaceutical products is likely to affect the stability of the ascorbic acid. Both Mg(...

Full description

Saved in:
Bibliographic Details
Main Author: Munigar, Milakanti
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/64441
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:64441
spelling id-itb.:644412022-05-24T09:23:09ZPENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II) Munigar, Milakanti Indonesia Final Project Ascorbic acid, HPLC, Mg(II), Zn(II), grinding INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/64441 Background and purpose: Ascorbic acid is a compound that relatively unstable to heat, and environmental influences such as light, oxidator and metal ions. The use of ascorbic acid in combination with minerals in pharmaceutical products is likely to affect the stability of the ascorbic acid. Both Mg(II) and Zn(II) are metal ions that often used with ascorbic acid in the commercial products. In addition, the energy involvement in the product production processes such as grinding, mixing, granulation, compression and others are likely to affect the stability of ascorbic acid. The purpose of this research is to determine the effect of ascorbic acid grinding with and without Mg(II) and Zn(II) to the levels of ascorbic acid. Methods: Simulation samples were made with ascorbic acid grinded with and without Mg(II) or Zn(II) for 1 hour and samples were taken every 10 minutes. Ascorbic acid concentration measurements carried out using high performance liquid chromatography (HPLC) with methanol - 0.02 M phosphate buffer pH 2.8 (20:80) as mobile phase, C18 column, flow rate of 1 mL/min, temperature of 25°C, and X 244 nm. Results: Concentration levels decrease of grinded ascorbic acid with Mg(II) is 73.64%. Whereas grinded ascorbic acid with Zn(II) did not provide significant decline of concentration levels. Conclusion: Grinded ascorbic acid with Mg(II) showed a significant concentration levels decrease. Whereas grinded ascorbic acid with Zn(II) did not provide significant decline of concentration levels. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Background and purpose: Ascorbic acid is a compound that relatively unstable to heat, and environmental influences such as light, oxidator and metal ions. The use of ascorbic acid in combination with minerals in pharmaceutical products is likely to affect the stability of the ascorbic acid. Both Mg(II) and Zn(II) are metal ions that often used with ascorbic acid in the commercial products. In addition, the energy involvement in the product production processes such as grinding, mixing, granulation, compression and others are likely to affect the stability of ascorbic acid. The purpose of this research is to determine the effect of ascorbic acid grinding with and without Mg(II) and Zn(II) to the levels of ascorbic acid. Methods: Simulation samples were made with ascorbic acid grinded with and without Mg(II) or Zn(II) for 1 hour and samples were taken every 10 minutes. Ascorbic acid concentration measurements carried out using high performance liquid chromatography (HPLC) with methanol - 0.02 M phosphate buffer pH 2.8 (20:80) as mobile phase, C18 column, flow rate of 1 mL/min, temperature of 25°C, and X 244 nm. Results: Concentration levels decrease of grinded ascorbic acid with Mg(II) is 73.64%. Whereas grinded ascorbic acid with Zn(II) did not provide significant decline of concentration levels. Conclusion: Grinded ascorbic acid with Mg(II) showed a significant concentration levels decrease. Whereas grinded ascorbic acid with Zn(II) did not provide significant decline of concentration levels.
format Final Project
author Munigar, Milakanti
spellingShingle Munigar, Milakanti
PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)
author_facet Munigar, Milakanti
author_sort Munigar, Milakanti
title PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)
title_short PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)
title_full PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)
title_fullStr PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)
title_full_unstemmed PENGEMBANGAN METODE KROMATOGRAFI CAIR KINERJA TINGGI UNTUK ANALISIS ASAM ASKORBAT DALAM SAMPEL PADAT YANG MENGANDUNG MG(II) DAN ZN(II)
title_sort pengembangan metode kromatografi cair kinerja tinggi untuk analisis asam askorbat dalam sampel padat yang mengandung mg(ii) dan zn(ii)
url https://digilib.itb.ac.id/gdl/view/64441
_version_ 1822004566405677056