OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA

In general, the characteristics of wastewater generated from hospitals are similar to domestic wastewater, but some of the hospital wastewater contains toxic pollutants, nonbiodegradable, and infectious pollutants. Hospital wastewater contains various substances used for medical, laboratory, a...

Full description

Saved in:
Bibliographic Details
Main Author: Razansyah, Fauzan
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/65051
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:65051
spelling id-itb.:650512022-06-20T11:02:02ZOVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA Razansyah, Fauzan Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Final Project Liquid waste, hospitals, WWTP systems, pharmaceutically active compounds, advanced oxidation processes INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/65051 In general, the characteristics of wastewater generated from hospitals are similar to domestic wastewater, but some of the hospital wastewater contains toxic pollutants, nonbiodegradable, and infectious pollutants. Hospital wastewater contains various substances used for medical, laboratory, and research purposes and includes waste from patients, including pharmaceutically active compounds (PhACs). Therefore, to design a WWTP system in hospitals, research on PhACs is needed. In addition, in-hospital waste is also commonly found bacteria and viruses that are harmful to humans. This research aim to identify the pollutants in hospital effluent and to determine a WWTP system capable of efficiently treating hospital effluent. The research was conducted at RSUD Majalengka, Majalengka City. Data on the characteristics of liquid waste were obtained from RSUD Majalengka, while data on non-domestic liquid waste treatment processes were obtained based on research conducted by researchers. The analyzed data proves that the WWTP system at the RSUD is efficient enough to treat domestic liquid waste, but the WWTP system at the RSUD Majalengka is still not able to process non-domestic liquid waste originating from activities in outpatient units, inpatient units, laboratories, emergency installations. emergency, pharmacy, and radiology. Therefore, in this study, a technology that was able to degrade PhACs was determined based on the research that had been done. The selected technology that will be designed to treat the liquid waste of Majalengka Hospital is an advanced ozone-based oxidation process. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik saniter dan perkotaan; teknik perlindungan lingkungan
spellingShingle Teknik saniter dan perkotaan; teknik perlindungan lingkungan
Razansyah, Fauzan
OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA
description In general, the characteristics of wastewater generated from hospitals are similar to domestic wastewater, but some of the hospital wastewater contains toxic pollutants, nonbiodegradable, and infectious pollutants. Hospital wastewater contains various substances used for medical, laboratory, and research purposes and includes waste from patients, including pharmaceutically active compounds (PhACs). Therefore, to design a WWTP system in hospitals, research on PhACs is needed. In addition, in-hospital waste is also commonly found bacteria and viruses that are harmful to humans. This research aim to identify the pollutants in hospital effluent and to determine a WWTP system capable of efficiently treating hospital effluent. The research was conducted at RSUD Majalengka, Majalengka City. Data on the characteristics of liquid waste were obtained from RSUD Majalengka, while data on non-domestic liquid waste treatment processes were obtained based on research conducted by researchers. The analyzed data proves that the WWTP system at the RSUD is efficient enough to treat domestic liquid waste, but the WWTP system at the RSUD Majalengka is still not able to process non-domestic liquid waste originating from activities in outpatient units, inpatient units, laboratories, emergency installations. emergency, pharmacy, and radiology. Therefore, in this study, a technology that was able to degrade PhACs was determined based on the research that had been done. The selected technology that will be designed to treat the liquid waste of Majalengka Hospital is an advanced ozone-based oxidation process.
format Final Project
author Razansyah, Fauzan
author_facet Razansyah, Fauzan
author_sort Razansyah, Fauzan
title OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA
title_short OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA
title_full OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA
title_fullStr OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA
title_full_unstemmed OVERVIEW OF ALTERNATIVE LIQUID WASTE TREATMENT SYSTEMS IN RSUD MAJALENGKA
title_sort overview of alternative liquid waste treatment systems in rsud majalengka
url https://digilib.itb.ac.id/gdl/view/65051
_version_ 1822004742512967680