PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS

ABSTRACT: <br /> <br /> Preconcentration technique for ion Cadmium (II) based on flow injection analysis using DOWEX 50WX-8 cation exchange resin packed on mini-coloumn with atomic absorption spectrophotometer as detector has been done. HCl solution concentration 3 M was used as an eluti...

Full description

Saved in:
Bibliographic Details
Main Author: Ambarsari (NIM 105 03 026), Novita
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/6553
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:6553
spelling id-itb.:65532017-09-27T11:42:32ZPRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS Ambarsari (NIM 105 03 026), Novita Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/6553 ABSTRACT: <br /> <br /> Preconcentration technique for ion Cadmium (II) based on flow injection analysis using DOWEX 50WX-8 cation exchange resin packed on mini-coloumn with atomic absorption spectrophotometer as detector has been done. HCl solution concentration 3 M was used as an elution agent and an aqua deionization is used as an carrier. This research show the retention capacity of Dowex 50WX-8 mini-coloumn is 0,135 mg Cd (II) per gram resin. Optimum volume of Cd (II) solution which can be retained by resin is 5 mL. Optimum volume of HCl 3 M is needed to elution Cd (II) from minicoloumn is 1 mL. The precision expresses as coefficient variation for concentration 100 ppb is 3,83 %. The sensitivity and limit of detection obtain respectively 0,34 ppb and 3,41 ppb. The linier range can be attained between 5 ppb until 200 ppb; with a correlation coefficient is 0,9866. These method has a good accuracy, according to % recovery > 95 %. The study of analytical performance showed this method can be used to analysis Cd (II) on a trace concentration (ppb) in water sample. Cd (II) in water sample from Citarum river shows under limit of detection of this methode, while water sample from Saguling Lake show concentration of Cd (II) is 9 ppb and 16 ppb. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description ABSTRACT: <br /> <br /> Preconcentration technique for ion Cadmium (II) based on flow injection analysis using DOWEX 50WX-8 cation exchange resin packed on mini-coloumn with atomic absorption spectrophotometer as detector has been done. HCl solution concentration 3 M was used as an elution agent and an aqua deionization is used as an carrier. This research show the retention capacity of Dowex 50WX-8 mini-coloumn is 0,135 mg Cd (II) per gram resin. Optimum volume of Cd (II) solution which can be retained by resin is 5 mL. Optimum volume of HCl 3 M is needed to elution Cd (II) from minicoloumn is 1 mL. The precision expresses as coefficient variation for concentration 100 ppb is 3,83 %. The sensitivity and limit of detection obtain respectively 0,34 ppb and 3,41 ppb. The linier range can be attained between 5 ppb until 200 ppb; with a correlation coefficient is 0,9866. These method has a good accuracy, according to % recovery > 95 %. The study of analytical performance showed this method can be used to analysis Cd (II) on a trace concentration (ppb) in water sample. Cd (II) in water sample from Citarum river shows under limit of detection of this methode, while water sample from Saguling Lake show concentration of Cd (II) is 9 ppb and 16 ppb.
format Final Project
author Ambarsari (NIM 105 03 026), Novita
spellingShingle Ambarsari (NIM 105 03 026), Novita
PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS
author_facet Ambarsari (NIM 105 03 026), Novita
author_sort Ambarsari (NIM 105 03 026), Novita
title PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS
title_short PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS
title_full PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS
title_fullStr PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS
title_full_unstemmed PRECONCENTRATION OF CADMIUM (II) BY USING DOWEX 50WX-8 RESIN BASED ON FLOW INJECTION ANALYSIS
title_sort preconcentration of cadmium (ii) by using dowex 50wx-8 resin based on flow injection analysis
url https://digilib.itb.ac.id/gdl/view/6553
_version_ 1820663920800563200