IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA

Abstract Maintaining the production of mature geothermal wells is difficult due to well integrity issues. Well integrity is the application of technical, operational, and organizational solutions to reduce the risk of uncontrolled release of formation fluids either into or out of the wellbore throu...

Full description

Saved in:
Bibliographic Details
Main Author: Adi Wicaksana, Artahsasta
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/66142
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:66142
spelling id-itb.:661422022-06-27T10:56:30ZIDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA Adi Wicaksana, Artahsasta Pertambangan dan operasi berkaitan Indonesia Final Project geothermal wellbore, well integrity, casing design, casing failure INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/66142 Abstract Maintaining the production of mature geothermal wells is difficult due to well integrity issues. Well integrity is the application of technical, operational, and organizational solutions to reduce the risk of uncontrolled release of formation fluids either into or out of the wellbore throughout the life cycle of a well (OLF and TBL, 2013). Such problems are more likely to occur in wells built to oil and gas standards. This will be exacerbated by the extreme geothermal environment. Since acquiring the X geothermal field, one of Indonesia’s longest-operated geothermal fields, PT X has faced difficulties as the operator. Casing issues have forced the abandonment of about half of the production wells. In order to increase production, the operator intends to reactivate abandoned wells. An initial study was conducted to assess the technical feasibility of reactivating wells at X field. The development of the well assessment methodology comprised casing design, historical data analysis, well problem identification, and investigation of well integrity. The study focused on the identification and characterization of two abandoned wells, XX9 and XX28, as well as current casing conditions, limitations, and challenges in performing a realistic, measurable, economical, and technically feasible well intervention and workover. The results of this study will be used to develop casing designs for future wells (Marbun et al, 2019). text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Pertambangan dan operasi berkaitan
spellingShingle Pertambangan dan operasi berkaitan
Adi Wicaksana, Artahsasta
IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA
description Abstract Maintaining the production of mature geothermal wells is difficult due to well integrity issues. Well integrity is the application of technical, operational, and organizational solutions to reduce the risk of uncontrolled release of formation fluids either into or out of the wellbore throughout the life cycle of a well (OLF and TBL, 2013). Such problems are more likely to occur in wells built to oil and gas standards. This will be exacerbated by the extreme geothermal environment. Since acquiring the X geothermal field, one of Indonesia’s longest-operated geothermal fields, PT X has faced difficulties as the operator. Casing issues have forced the abandonment of about half of the production wells. In order to increase production, the operator intends to reactivate abandoned wells. An initial study was conducted to assess the technical feasibility of reactivating wells at X field. The development of the well assessment methodology comprised casing design, historical data analysis, well problem identification, and investigation of well integrity. The study focused on the identification and characterization of two abandoned wells, XX9 and XX28, as well as current casing conditions, limitations, and challenges in performing a realistic, measurable, economical, and technically feasible well intervention and workover. The results of this study will be used to develop casing designs for future wells (Marbun et al, 2019).
format Final Project
author Adi Wicaksana, Artahsasta
author_facet Adi Wicaksana, Artahsasta
author_sort Adi Wicaksana, Artahsasta
title IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA
title_short IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA
title_full IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA
title_fullStr IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA
title_full_unstemmed IDENTIFIKASI KEGAGALAN CASING PADA SUMUR GEOTERMAL BERSTATUS ABANDONED DI LAPANGAN X, INDONESIA
title_sort identifikasi kegagalan casing pada sumur geotermal berstatus abandoned di lapangan x, indonesia
url https://digilib.itb.ac.id/gdl/view/66142
_version_ 1822932954044694528