#TITLE_ALTERNATIVE#
Abstract: <br /> <br /> <br /> <br /> Recently, instant noodle producers increase their quality product by vitamins fortification. <br /> <br /> <br /> <br /> In this research, an analytical method applying high performance liquid chromatography...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/6799 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | Abstract: <br />
<br />
<br />
<br />
Recently, instant noodle producers increase their quality product by vitamins fortification. <br />
<br />
<br />
<br />
In this research, an analytical method applying high performance liquid chromatography <br />
<br />
<br />
<br />
technique (HPLC) for determination of water-soluble vitamins in instant noodle was <br />
<br />
<br />
<br />
developed. Prior the determination, the analytes were triturated using acetate buffer of pH <br />
<br />
<br />
<br />
3.5 as extracting solvent and further purified by means of SPE method. An HPLC and solid <br />
<br />
<br />
<br />
phase extraction (SPE) method were developed to analyze water-soluble vitamins in <br />
<br />
<br />
<br />
instant noodle. An isocratic HPLC system under following conditions: methanol and 5 <br />
<br />
<br />
<br />
mM 1-hexanesulfonic acid solution in 1 percent aquaeous acetic acid solution adjusted to pH 3.5 <br />
<br />
<br />
<br />
with trietilamine (18.5:81.5) as eluting solvent, flow rate of 2 mL/min, as well as detection <br />
<br />
<br />
<br />
at 275 nm; were suitable for the determination of water soluble vitamins. Under this <br />
<br />
<br />
<br />
condition vitamin B1, B3, B6, and B11 gave limit of detection of 0.13, 0.26, 0.14, and <br />
<br />
<br />
<br />
0.08 ppm; as well as limit of quantitation of 0.47, 0.86, 0.47, and 0.28 ppm, respectively. <br />
<br />
<br />
<br />
The precision of the determination of vitamin B1, B3, B6, and B11, stated as coefficient of <br />
<br />
<br />
<br />
variation (CV), were respectively 2.36, 0.38, 2.40, and 0.78 percent, while their accuracy stated <br />
<br />
<br />
<br />
as percentage of recovery, were respectively 82,73 - 89,18, 87,76 - 97,00, 87,71 - 96,69, <br />
<br />
<br />
<br />
and 242,41 - 440,07 percent. Generally, this method gave good precision and accuracy for <br />
<br />
<br />
<br />
determination vitamin B1, B3, and B6 in instant noodle. |
---|