UPPER STRUCTURE DESIGN OF MULTIPURPOSE BUILDING ITB CIREBON CAMPUS
This final project discusses about upper structure design of multipurpose building ITB Cirebon Campus. Structure is designed to resist gravitation and earthquake load. This project is located in Kabupaten Cirebon, Kelurahan Arjawinangun on Jalan Raya Pantura with soil site classification is soft...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/68813 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | This final project discusses about upper structure design of multipurpose building ITB
Cirebon Campus. Structure is designed to resist gravitation and earthquake load. This
project is located in Kabupaten Cirebon, Kelurahan Arjawinangun on Jalan Raya
Pantura with soil site classification is soft soil SE and risk category is type IV thus
building is classified as D in seismic design category. This project consist of 1-story
basement as parking area and 3-story as classroom and corridor. Structure is modeled
using software ETABS and designed based on SNI 1726:2019 for earthquake
resistance design, SNI 1727:2020 for minimum design load criteria, and SNI
2847:2019 for reinforced concrete building design.
Structure system of multipurpose building ITB Cirebon Campus is designed with
special moment frames (SMF) as the seismic force resisting system. Slab is designed
using SAFE20 software. Column is design using sPColumn software. The result of this
design are structural analysis and earthquake resistant structural element design
designated as part of seismic force resisting system.
|
---|