RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY)
The quality of the water environment is crucial to fulfilling everyone's right to a decent environment. One of the efforts to prevent the entry of contaminants from residential into water bodies is to utilize domestic wastewater treatment technology. Maleer Domestic WWTP treats domestic wast...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/69310 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:69310 |
---|---|
spelling |
id-itb.:693102022-09-21T12:54:59ZRISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) Inarah Rahmat Hasby, Farisah Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Theses Cikapundung Kolot River, Coliform Bacteria, Escherichia coli, Domestic WWTP, QMRA. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/69310 The quality of the water environment is crucial to fulfilling everyone's right to a decent environment. One of the efforts to prevent the entry of contaminants from residential into water bodies is to utilize domestic wastewater treatment technology. Maleer Domestic WWTP treats domestic wastewater from 63 house connections with Anaerobic Upflow Filter (AUF) technology. Although the WWTP is expected to prevent contamination, the results of the Maleer WWTP processing have not met the quality standards of the Minister of Environment Regulation No. 68 of 2016. this condition is indicated to have a polluting effect on the Cikapundung Kolot River and groundwater, which also contains Coliform bacteria. This study aims to measure the risk of Coliform bacterial contamination in the water environment around the Maleer Domestic IPAL on the health of residents to determine the appropriate concept of environmental management. Risk analysis uses the Quantitative Microbial Risk Assessment (QMRA) method. The concentration of E. coli bacteria in clean water and residents' drinking water was measured using the Multiple Tube Fermentation method with the Most Probable Number concept. All sources of clean water and drinking water for residents are unsuitable because they contain E. coli bacteria. The probability of daily infection from E. coli contamination was calculated using the Beta-Poisson Model and it was found that the highest risk was from drinking (0.132). Based on the type of water source used, dug wells provide the greatest daily infection probability (0.251). Repeated exposure in one year to the same water source gives the potential for infection of 1. This value exceeds the WHO limit of 0.0001, so the water source is not suitable for use in daily hygiene and sanitation activities. Tackling environmental problems in Maleer Village can be applied by involving various parties to manage wastewater by installing disinfection, monitoring, and maintenance of WWTP; maintaining the quality of the Cikapundung Kolot River by stopping BABS activities and disposing of garbage in the river; ensuring the quality of water sources is maintained at the source and shelter; maintain a healthy and clean lifestyle. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan |
spellingShingle |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan Inarah Rahmat Hasby, Farisah RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) |
description |
The quality of the water environment is crucial to fulfilling everyone's right to a
decent environment. One of the efforts to prevent the entry of contaminants from
residential into water bodies is to utilize domestic wastewater treatment technology.
Maleer Domestic WWTP treats domestic wastewater from 63 house connections
with Anaerobic Upflow Filter (AUF) technology. Although the WWTP is expected
to prevent contamination, the results of the Maleer WWTP processing have not met
the quality standards of the Minister of Environment Regulation No. 68 of 2016.
this condition is indicated to have a polluting effect on the Cikapundung Kolot River
and groundwater, which also contains Coliform bacteria. This study aims to
measure the risk of Coliform bacterial contamination in the water environment
around the Maleer Domestic IPAL on the health of residents to determine the
appropriate concept of environmental management. Risk analysis uses the
Quantitative Microbial Risk Assessment (QMRA) method. The concentration of E.
coli bacteria in clean water and residents' drinking water was measured using the
Multiple Tube Fermentation method with the Most Probable Number concept. All
sources of clean water and drinking water for residents are unsuitable because they
contain E. coli bacteria. The probability of daily infection from E. coli
contamination was calculated using the Beta-Poisson Model and it was found that
the highest risk was from drinking (0.132). Based on the type of water source used,
dug wells provide the greatest daily infection probability (0.251). Repeated
exposure in one year to the same water source gives the potential for infection of 1.
This value exceeds the WHO limit of 0.0001, so the water source is not suitable for
use in daily hygiene and sanitation activities. Tackling environmental problems in
Maleer Village can be applied by involving various parties to manage wastewater
by installing disinfection, monitoring, and maintenance of WWTP; maintaining the
quality of the Cikapundung Kolot River by stopping BABS activities and disposing
of garbage in the river; ensuring the quality of water sources is maintained at the
source and shelter; maintain a healthy and clean lifestyle. |
format |
Theses |
author |
Inarah Rahmat Hasby, Farisah |
author_facet |
Inarah Rahmat Hasby, Farisah |
author_sort |
Inarah Rahmat Hasby, Farisah |
title |
RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) |
title_short |
RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) |
title_full |
RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) |
title_fullStr |
RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) |
title_full_unstemmed |
RISK ANALYSIS OF COLIFORM BACTERIA CONTAMINATION IN THE WATER ENVIRONMENT AROUND RESIDENTIAL AREA RECEIVING DOMESTIC WWTP EFFLUENT (CASE STUDY: MALEER DOMESTIC WWTP, BANDUNG CITY) |
title_sort |
risk analysis of coliform bacteria contamination in the water environment around residential area receiving domestic wwtp effluent (case study: maleer domestic wwtp, bandung city) |
url |
https://digilib.itb.ac.id/gdl/view/69310 |
_version_ |
1822006015844941824 |