APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X
Air pollution is the entry or inclusion of substances, energy, from other components into the ambient air by human activities so that air quality decreases to a certain level. To protect an area from air pollution, it is necessary to have a strategy to manage air quality, one of which is by predic...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/69375 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:69375 |
---|---|
spelling |
id-itb.:693752022-09-21T19:47:28ZAPPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X Sekar Sarinastiti, Anneke Indonesia Final Project AERMOD, air pollution, ambient, CALPUFF, concentration, dispersion, and modeling INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/69375 Air pollution is the entry or inclusion of substances, energy, from other components into the ambient air by human activities so that air quality decreases to a certain level. To protect an area from air pollution, it is necessary to have a strategy to manage air quality, one of which is by predicting the dispersion of pollutants from a source using a modeling application. study area, and accuracy of prediction results with actual concentrations in ambient. In this study, two modeling applications were used, namely the Lagrangian-based CALPUFF model, non-steady state, and the Gaussian Plume-based, steady state AERMOD model. This research was conducted in Central Cikarang District, Bekasi Regency, with pollutant emission sources TSP, SO2, and NO2 from the chimney of PT. X. To determine the accuracy of the two models, several types of statistical tests are used, namely correlation coefficient (R), Index of Agreement (IOA), Fractional Bias (FB), Root Mean Square Error (RMSE), Error, and Mean Bias (MB). The results of this study indicate that the highest concentration for each pollutant and its location has different values in CALPUFF and AERMOD. CALPUFF always yielded higher values in the highest predicted concentrations (0.4129 µg/m3 for TSP, 0.6183 µg/m3 for SO2, and 0.5016 µg/m3 for NO2) than AERMOD (0.1256 µg/m3 for TSP, 0.2787 µg/m3 for SO2, and 0.2258 µg/m3 for NO2). Overall, CALPUFF has a better performance in modeling TSP, SO2, and NO2 pollutants than AERMOD as evidenced by statistical tests on the results of the dispersion of the two models. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Air pollution is the entry or inclusion of substances, energy, from other components into the
ambient air by human activities so that air quality decreases to a certain level. To protect an area from air
pollution, it is necessary to have a strategy to manage air quality, one of which is by predicting the dispersion of
pollutants from a source using a modeling application. study area, and accuracy of prediction results with actual
concentrations in ambient. In this study, two modeling applications were used, namely the Lagrangian-based
CALPUFF model, non-steady state, and the Gaussian Plume-based, steady state AERMOD model. This research
was conducted in Central Cikarang District, Bekasi Regency, with pollutant emission sources TSP, SO2, and NO2
from the chimney of PT. X. To determine the accuracy of the two models, several types of statistical tests are
used, namely correlation coefficient (R), Index of Agreement (IOA), Fractional Bias (FB), Root Mean Square
Error (RMSE), Error, and Mean Bias (MB). The results of this study indicate that the highest concentration for
each pollutant and its location has different values in CALPUFF and AERMOD. CALPUFF always yielded
higher values in the highest predicted concentrations (0.4129 µg/m3
for TSP, 0.6183 µg/m3
for SO2, and 0.5016
µg/m3
for NO2) than AERMOD (0.1256 µg/m3
for TSP, 0.2787 µg/m3
for SO2, and 0.2258 µg/m3
for NO2).
Overall, CALPUFF has a better performance in modeling TSP, SO2, and NO2 pollutants than AERMOD as
evidenced by statistical tests on the results of the dispersion of the two models.
|
format |
Final Project |
author |
Sekar Sarinastiti, Anneke |
spellingShingle |
Sekar Sarinastiti, Anneke APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X |
author_facet |
Sekar Sarinastiti, Anneke |
author_sort |
Sekar Sarinastiti, Anneke |
title |
APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X |
title_short |
APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X |
title_full |
APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X |
title_fullStr |
APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X |
title_full_unstemmed |
APPLICATION AND PERFORMANCE EVALUATION OF CALPUFF DAN AERMOD MODELING SYSTEM TO SIMULATE TSP, SO2, AND NO2 POLLUTANT DISPERSIONI : A CASE STUDY AT PT. X |
title_sort |
application and performance evaluation of calpuff dan aermod modeling system to simulate tsp, so2, and no2 pollutant dispersioni : a case study at pt. x |
url |
https://digilib.itb.ac.id/gdl/view/69375 |
_version_ |
1822991021577863168 |