FAILURE MODE AND EFFECT ANALYSIS (FMEA) AND PREVENTIVE MAINTENANCE SELECTION ON PULVERIZER USING QUANTITATIVE MSG-3 METHOD

A coal-fired power plant that can produce 740 MW of electricity had a failure in one of the production equipment, the pulverizer machine, resulting in the interruption of the production activity (downtime). A pulverizer machine is a crucial equipment that needs to be given maintenance in order to so...

Full description

Saved in:
Bibliographic Details
Main Author: Daniswara Izadd, Afgar
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/70574
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia