STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS

Co-based metal alloys are future biomaterials for heart valve implant applications due to their excellent biocompatibility, mechanical, and corrosion properties. The CoCrWNiMn alloys, one of cobalt-based alloys, is currently being researched as a biomaterial. Boron has long been used as an alloyi...

Full description

Saved in:
Bibliographic Details
Main Author: Ilham Maulana, Muhammad
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/71615
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:71615
spelling id-itb.:716152023-02-16T11:14:19ZSTUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS Ilham Maulana, Muhammad Indonesia Theses Boron-added, CoCrWNiMn Alloys, In Vivo, Vacuum Arc Remelting. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/71615 Co-based metal alloys are future biomaterials for heart valve implant applications due to their excellent biocompatibility, mechanical, and corrosion properties. The CoCrWNiMn alloys, one of cobalt-based alloys, is currently being researched as a biomaterial. Boron has long been used as an alloying element which is added in certain amounts to several alloys. In this study, boron was used as an alloying element in the CoCrWNiMn alloys to modifying its mechanical and corrosion properties. The CoCrWNiMn alloys was prepared from cobalt, chrome, wolfram, nickel, mangan, and boron chunk metals using vacuum arc remelting under Argon atmosphere. The Vacuum Arc Remelting (VAR) process for each sample was carried out 6 times by back and forth to obtain a uniformity distribution of elements in each part. The microstructure, mechanical, and corrosion properties of the CoCrWNiMn-×B alloys were analyzed. This analysis included optical microscopy observations, SEM-EDS mapping observations, OES, XRD, hardness test, tensile test, density test and corrosion performances of CoCrWNiMn-×B alloys in Hanks' solution. The results showed that boron addition up to 0.8 wt% in the CoCrWNiMn alloys did not change phases significantly, but led precipitates at grain boundaries on the sample morphology. Hardness and tensile strength properties of the CoCrWNiMn alloy increased with boron addition. CoCrWNiMn alloys with 0.8 wt% boron addition produced the highest hardness and yield strength values in 32.74 HRC and 439.27 MPa. The corrosion performances of the CoCrWNiMn alloys in Hanks' solution decreased with boron addition. In-vivo corrosion results showed that the CoCrWNiMn alloys with 0.8 wt% boron addition had the highest electrical resistance, which leads a decrease in the corrosion rate. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Co-based metal alloys are future biomaterials for heart valve implant applications due to their excellent biocompatibility, mechanical, and corrosion properties. The CoCrWNiMn alloys, one of cobalt-based alloys, is currently being researched as a biomaterial. Boron has long been used as an alloying element which is added in certain amounts to several alloys. In this study, boron was used as an alloying element in the CoCrWNiMn alloys to modifying its mechanical and corrosion properties. The CoCrWNiMn alloys was prepared from cobalt, chrome, wolfram, nickel, mangan, and boron chunk metals using vacuum arc remelting under Argon atmosphere. The Vacuum Arc Remelting (VAR) process for each sample was carried out 6 times by back and forth to obtain a uniformity distribution of elements in each part. The microstructure, mechanical, and corrosion properties of the CoCrWNiMn-×B alloys were analyzed. This analysis included optical microscopy observations, SEM-EDS mapping observations, OES, XRD, hardness test, tensile test, density test and corrosion performances of CoCrWNiMn-×B alloys in Hanks' solution. The results showed that boron addition up to 0.8 wt% in the CoCrWNiMn alloys did not change phases significantly, but led precipitates at grain boundaries on the sample morphology. Hardness and tensile strength properties of the CoCrWNiMn alloy increased with boron addition. CoCrWNiMn alloys with 0.8 wt% boron addition produced the highest hardness and yield strength values in 32.74 HRC and 439.27 MPa. The corrosion performances of the CoCrWNiMn alloys in Hanks' solution decreased with boron addition. In-vivo corrosion results showed that the CoCrWNiMn alloys with 0.8 wt% boron addition had the highest electrical resistance, which leads a decrease in the corrosion rate.
format Theses
author Ilham Maulana, Muhammad
spellingShingle Ilham Maulana, Muhammad
STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS
author_facet Ilham Maulana, Muhammad
author_sort Ilham Maulana, Muhammad
title STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS
title_short STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS
title_full STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS
title_fullStr STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS
title_full_unstemmed STUDY ON MICROSTRUCTURE, MECHANICAL, AND CORROSION PROPERTIES OF B-ADDED CO-CR-W-NI-MN ALLOYS FOR HEART VALVE IMPLANT APPLICATIONS
title_sort study on microstructure, mechanical, and corrosion properties of b-added co-cr-w-ni-mn alloys for heart valve implant applications
url https://digilib.itb.ac.id/gdl/view/71615
_version_ 1822006634803625984