PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI
New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I-. The I- ion which is formed then oxidized on platinum electrode. The calibration plo...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/71712 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:71712 |
---|---|
spelling |
id-itb.:717122023-02-21T13:23:41ZPENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI Lesmana, Yoga Kimia Indonesia Final Project New amperometric INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/71712 New amperometric method using I2 as mediator for ascorbic acid analysis on platinum electrode has been developed. This method is based on oxidation of ascorbic acid by I2, resulting in dehydroascorbic acid and I-. The I- ion which is formed then oxidized on platinum electrode. The calibration plot in the concentration range of 0.01 – 8 mM showing good linearity with detection limit of 3.43 × 10-6 M. Application of this method to analyze ascorbic acid in vitamin C tablet, and healthy drink samples showing good results. On the other hand, analysis accuracy of multivitamine sample is low. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Kimia |
spellingShingle |
Kimia Lesmana, Yoga PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI |
description |
New amperometric method using I2 as mediator for ascorbic acid analysis on
platinum electrode has been developed. This method is based on oxidation of
ascorbic acid by I2, resulting in dehydroascorbic acid and I-. The I- ion which is
formed then oxidized on platinum electrode. The calibration plot in the concentration
range of 0.01 – 8 mM showing good linearity with detection limit of 3.43 × 10-6 M.
Application of this method to analyze ascorbic acid in vitamin C tablet, and healthy
drink samples showing good results. On the other hand, analysis accuracy of
multivitamine sample is low. |
format |
Final Project |
author |
Lesmana, Yoga |
author_facet |
Lesmana, Yoga |
author_sort |
Lesmana, Yoga |
title |
PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI |
title_short |
PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI |
title_full |
PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI |
title_fullStr |
PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI |
title_full_unstemmed |
PENGGUNAAN I2 SEBAGAI MEDIATOR PADA ANALISIS ASAM ASKORBAT SECARA AMPEROMETRI |
title_sort |
penggunaan i2 sebagai mediator pada analisis asam askorbat secara amperometri |
url |
https://digilib.itb.ac.id/gdl/view/71712 |
_version_ |
1822006662652755968 |