PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)

Water pollution by copper has been a common case. Monitoring the water pollution requires analysis method which is simple, sensitive, and has good detection limitation. Since the metal ion Cu(II) in the environment generally in trace level. One of ways to solve this problem is by using pre-concen...

Full description

Saved in:
Bibliographic Details
Main Author: Trijayanti, Astuti
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/71746
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:71746
spelling id-itb.:717462023-02-22T14:33:20ZPRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA) Trijayanti, Astuti Kimia Indonesia Final Project Water pollution INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/71746 Water pollution by copper has been a common case. Monitoring the water pollution requires analysis method which is simple, sensitive, and has good detection limitation. Since the metal ion Cu(II) in the environment generally in trace level. One of ways to solve this problem is by using pre-concentration based on FIA technique. In this research, an analytical method using modified polistiren divinilbenzen resin with ?-nitroso-?-naftol has been developed and evaluated. The modified resin has a retention capacity of 0.56 mg Cu(II)/g resin on pH 6.50 with minimum contact time of 11 minutes. The retention characteristics of resin has enabled to use it as mini column filling material for pre-concentration based on FIA. A 0.60 mL of 1 M nitric acid was capable to quantitatively elute of retained metal Cu(II). Analytical performance from the develop method is very well as shown by the detection limit of 1.68 ppb, with good linearity in concentration range 20–300 ppb. Application of developed method in water sample analysis results recovery by 97.24%. The result obtained shows that developed pre-concentration method can be used for trace analysis of copper in the environment. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Kimia
spellingShingle Kimia
Trijayanti, Astuti
PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)
description Water pollution by copper has been a common case. Monitoring the water pollution requires analysis method which is simple, sensitive, and has good detection limitation. Since the metal ion Cu(II) in the environment generally in trace level. One of ways to solve this problem is by using pre-concentration based on FIA technique. In this research, an analytical method using modified polistiren divinilbenzen resin with ?-nitroso-?-naftol has been developed and evaluated. The modified resin has a retention capacity of 0.56 mg Cu(II)/g resin on pH 6.50 with minimum contact time of 11 minutes. The retention characteristics of resin has enabled to use it as mini column filling material for pre-concentration based on FIA. A 0.60 mL of 1 M nitric acid was capable to quantitatively elute of retained metal Cu(II). Analytical performance from the develop method is very well as shown by the detection limit of 1.68 ppb, with good linearity in concentration range 20–300 ppb. Application of developed method in water sample analysis results recovery by 97.24%. The result obtained shows that developed pre-concentration method can be used for trace analysis of copper in the environment.
format Final Project
author Trijayanti, Astuti
author_facet Trijayanti, Astuti
author_sort Trijayanti, Astuti
title PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)
title_short PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)
title_full PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)
title_fullStr PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)
title_full_unstemmed PRAKONSENTRASI DAN ANALISIS ION LOGAM CU(II) BERBASIS ANALISIS INJEKSI ALIR (FIA)
title_sort prakonsentrasi dan analisis ion logam cu(ii) berbasis analisis injeksi alir (fia)
url https://digilib.itb.ac.id/gdl/view/71746
_version_ 1822006670525464576