DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER

Padalarang Fly Over is an alternative that is used to overcome problems related to performance at the Padalarang intersection. This fly over connects the Kota Baru Parahyangan access road with the Padalarang toll gate, thereby reducing vehicle conflicts that occur at intersections. Padalarang Fl...

Full description

Saved in:
Bibliographic Details
Main Author: Faisal Mumtaz, Rezaldy
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/72070
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:72070
spelling id-itb.:720702023-03-03T10:26:38ZDESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER Faisal Mumtaz, Rezaldy Teknik sipil Indonesia Final Project bored pile foundation, cantilever retaining wall, LPILE, Ensoft GROUP INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/72070 Padalarang Fly Over is an alternative that is used to overcome problems related to performance at the Padalarang intersection. This fly over connects the Kota Baru Parahyangan access road with the Padalarang toll gate, thereby reducing vehicle conflicts that occur at intersections. Padalarang Fly Over has a width of 24.24 meters and a total length of 292 meters, consisting of 6 bridge spans supported by 5 pillars and 2 abutments. This final project discusses the design of foundations that can withstand the loading of bridge structures and retaining walls that are able to hold the soil as needed safely. The cantilever retaining wall is used to hold the embankment of the approach road at points A1 and A2 at 6.378 meters and 4.628 meters. In the wall design, a design with a wall height of 7.778 meters and 6.028 meters and a plate width of 5.445 meters and 4.22 meters are used. The bored pile foundation is used with a diameter of 1 meter and 1.2 meters with a tip depth of 19-26 meters. In the foundation design, an analysis is carried out on the single axial compression bearing capacity, single axial tensile bearing capacity, lateral bearing capacity using LPILE software, pile group bearing capacity using Ensoft GROUP software, and foundation settlement. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
Faisal Mumtaz, Rezaldy
DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER
description Padalarang Fly Over is an alternative that is used to overcome problems related to performance at the Padalarang intersection. This fly over connects the Kota Baru Parahyangan access road with the Padalarang toll gate, thereby reducing vehicle conflicts that occur at intersections. Padalarang Fly Over has a width of 24.24 meters and a total length of 292 meters, consisting of 6 bridge spans supported by 5 pillars and 2 abutments. This final project discusses the design of foundations that can withstand the loading of bridge structures and retaining walls that are able to hold the soil as needed safely. The cantilever retaining wall is used to hold the embankment of the approach road at points A1 and A2 at 6.378 meters and 4.628 meters. In the wall design, a design with a wall height of 7.778 meters and 6.028 meters and a plate width of 5.445 meters and 4.22 meters are used. The bored pile foundation is used with a diameter of 1 meter and 1.2 meters with a tip depth of 19-26 meters. In the foundation design, an analysis is carried out on the single axial compression bearing capacity, single axial tensile bearing capacity, lateral bearing capacity using LPILE software, pile group bearing capacity using Ensoft GROUP software, and foundation settlement.
format Final Project
author Faisal Mumtaz, Rezaldy
author_facet Faisal Mumtaz, Rezaldy
author_sort Faisal Mumtaz, Rezaldy
title DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER
title_short DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER
title_full DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER
title_fullStr DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER
title_full_unstemmed DESIGN OF BORED PILES AND CANTILEVER RETAINING WALLS FOR PADALARANG FLY OVER
title_sort design of bored piles and cantilever retaining walls for padalarang fly over
url https://digilib.itb.ac.id/gdl/view/72070
_version_ 1822006755964485632