MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS

Around 22.5 million people in Indonesia in 2020 are person with disabilities. From that 22.5 million people, around 38.3% have a disability that affect lower body movement such as standing, walking, or climbing stairs. Meanwhile, assistive device that can replace movement function in Indonesia are s...

Full description

Saved in:
Bibliographic Details
Main Author: Maulana, Fakhri
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/74265
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:74265
spelling id-itb.:742652023-06-27T13:37:11ZMANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS Maulana, Fakhri Indonesia Final Project exoskeleton, spinal cord injury, sit-to-stand, rehabilitation device INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/74265 Around 22.5 million people in Indonesia in 2020 are person with disabilities. From that 22.5 million people, around 38.3% have a disability that affect lower body movement such as standing, walking, or climbing stairs. Meanwhile, assistive device that can replace movement function in Indonesia are still relatively few and are expensive in the international market. The Biomechanics FTMD ITB research team has developed and designed an active assistive device for sitting to standing movements. However, the tool has not been fabricated and the capabilities of the tool have not been tested. Therefore, in this undergraduate project fabrication and testing is carried out. The work starts from reviewing the design to see whether has been made are affect the testing. Then proceed with the production of exoskeleton consisting of fabrication and assembly. After the exoskeleton is made, exoskeleton will be tested with 2 modes, testing without able-bodied subject and with able-bodied subject. Testing will be carried out using motion capture method to obtain the trajectory of exoskeleton when exoskeleton is use with and without able-bodied subject. Trajectory that been created from data motion capture processing when testing without able-bodied have similar trendline and little error if compare with encoder sensor. While trajectory that been created from testing with able-bodied subject have an error about 10 degreee in the hip section. This error is cause by obstruction of flexion movement in the hip due to the lack of space between the user’s abdomen and the user’s thighs. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Around 22.5 million people in Indonesia in 2020 are person with disabilities. From that 22.5 million people, around 38.3% have a disability that affect lower body movement such as standing, walking, or climbing stairs. Meanwhile, assistive device that can replace movement function in Indonesia are still relatively few and are expensive in the international market. The Biomechanics FTMD ITB research team has developed and designed an active assistive device for sitting to standing movements. However, the tool has not been fabricated and the capabilities of the tool have not been tested. Therefore, in this undergraduate project fabrication and testing is carried out. The work starts from reviewing the design to see whether has been made are affect the testing. Then proceed with the production of exoskeleton consisting of fabrication and assembly. After the exoskeleton is made, exoskeleton will be tested with 2 modes, testing without able-bodied subject and with able-bodied subject. Testing will be carried out using motion capture method to obtain the trajectory of exoskeleton when exoskeleton is use with and without able-bodied subject. Trajectory that been created from data motion capture processing when testing without able-bodied have similar trendline and little error if compare with encoder sensor. While trajectory that been created from testing with able-bodied subject have an error about 10 degreee in the hip section. This error is cause by obstruction of flexion movement in the hip due to the lack of space between the user’s abdomen and the user’s thighs.
format Final Project
author Maulana, Fakhri
spellingShingle Maulana, Fakhri
MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS
author_facet Maulana, Fakhri
author_sort Maulana, Fakhri
title MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS
title_short MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS
title_full MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS
title_fullStr MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS
title_full_unstemmed MANUFACTURING AND TESTING OF SIT-TO-STAND EXOSKELETON FOR PARAPLEGIC PATIENTS
title_sort manufacturing and testing of sit-to-stand exoskeleton for paraplegic patients
url https://digilib.itb.ac.id/gdl/view/74265
_version_ 1822993653745844224