PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR

Ozone is one of parameter in air quality that important to be measured and monitored. Excessive ozone exposure can have adverse effects humans and other living things, such as causing lung disease, disrupting the photosynthesis process of plants, and damaging living creature ecosystem. One of...

Full description

Saved in:
Bibliographic Details
Main Author: Avicenna A S, M
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/75190
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:75190
spelling id-itb.:751902023-07-25T15:38:18ZPERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR Avicenna A S, M Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Final Project Aeroqual S500, AQMS-300, equivalent method, low-cost ozone sensor, neutral buffer kalium iodida, referance method, UV-absorption INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/75190 Ozone is one of parameter in air quality that important to be measured and monitored. Excessive ozone exposure can have adverse effects humans and other living things, such as causing lung disease, disrupting the photosynthesis process of plants, and damaging living creature ecosystem. One of the low-cost measurement alternatives is a low-cost ozone sensor. This paper discusses the comparison of Aeroqual S500 measurement results with the method used as a national standard in Indonesia, neutral buffered kalium iodide (NBKI) (SNI 7119-8, 2017), as a reference method and UV Absorption method that used by DLH DKI Jakarta as equivalent method. Based on the results of this study, the accuracy and precision performance of the Aeroqual S500 is relatively good based on both method, especially equivalent method. The Aeroqual S500 measurement results have a precision of 80.147% for the combined frequency of 1 minute and 2 minutes. Where the Aeroqual S500 measurement results have preciosion a correlation (r = 0.579) with (p-value = 0.000) and regression (R2 = 0.3348) with NBKI. While Aeroqual S500 measurement results have a correlation (r = 0. 940) with (p-value = 0.000) and regression (R2 = 0.8845) with AQMS-300. RMSE (Root Mean Square Error) calculated the error range of Aeroqual S500 against equivalent method, which is 18,371 µg/m. 3 text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik saniter dan perkotaan; teknik perlindungan lingkungan
spellingShingle Teknik saniter dan perkotaan; teknik perlindungan lingkungan
Avicenna A S, M
PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR
description Ozone is one of parameter in air quality that important to be measured and monitored. Excessive ozone exposure can have adverse effects humans and other living things, such as causing lung disease, disrupting the photosynthesis process of plants, and damaging living creature ecosystem. One of the low-cost measurement alternatives is a low-cost ozone sensor. This paper discusses the comparison of Aeroqual S500 measurement results with the method used as a national standard in Indonesia, neutral buffered kalium iodide (NBKI) (SNI 7119-8, 2017), as a reference method and UV Absorption method that used by DLH DKI Jakarta as equivalent method. Based on the results of this study, the accuracy and precision performance of the Aeroqual S500 is relatively good based on both method, especially equivalent method. The Aeroqual S500 measurement results have a precision of 80.147% for the combined frequency of 1 minute and 2 minutes. Where the Aeroqual S500 measurement results have preciosion a correlation (r = 0.579) with (p-value = 0.000) and regression (R2 = 0.3348) with NBKI. While Aeroqual S500 measurement results have a correlation (r = 0. 940) with (p-value = 0.000) and regression (R2 = 0.8845) with AQMS-300. RMSE (Root Mean Square Error) calculated the error range of Aeroqual S500 against equivalent method, which is 18,371 µg/m. 3
format Final Project
author Avicenna A S, M
author_facet Avicenna A S, M
author_sort Avicenna A S, M
title PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR
title_short PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR
title_full PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR
title_fullStr PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR
title_full_unstemmed PERFORMANCE EVALUATION OF METAL SEMICONDUCTING SENSOR BY NBKI METHOD AND UV ABSORPTION METHOD IN OZONE MEASUREMENT IN AMBIENT AIR
title_sort performance evaluation of metal semiconducting sensor by nbki method and uv absorption method in ozone measurement in ambient air
url https://digilib.itb.ac.id/gdl/view/75190
_version_ 1822007606662660096