THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES

Vapor compression-type heat pumps are increasingly in demand as heaters because they have higher performance than gas, oil, or electric heaters. Existing compression heat pumps are used to heat water to a temperature of less than 80?. Heating temperatures in various process industries usually requir...

Full description

Saved in:
Bibliographic Details
Main Author: Paul Alfredo Purba, Rado
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/76267
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:76267
spelling id-itb.:762672023-08-14T10:24:26ZTHERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES Paul Alfredo Purba, Rado Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Final Project Thermodynamics analysis, heat pump, refrigerant, performance INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/76267 Vapor compression-type heat pumps are increasingly in demand as heaters because they have higher performance than gas, oil, or electric heaters. Existing compression heat pumps are used to heat water to a temperature of less than 80?. Heating temperatures in various process industries usually require more than 100?. This heat pump uses a working fluid (refrigerant) which may harm the environment. For this reason, a system that can reach high temperatures with high performance and uses environmentally friendly refrigerants is needed. One development that can be made is the implementation of a cascade system. Therefore, this study analyzes the thermodynamics and environmental aspects of a three-stage heat pump system with temperatures up to 150ºC. This research begins with calculating the ideal Carnot refrigeration cycle for each stage. The study parameters include condensation temperature for each stage, global warming and ozone depletion potential, performance, and refrigerant safety class. Performance calculation of the vapor compression cycle uses the condensing temperature with the appropriate refrigerant for each stage. Refrigerant pairs obtained are then compared to each other based on performance, impact on the environment, and risk of use. The simulation shows the highest performance using methyl oleate, cyclopentane, and water can achieve performance of 2.07. The multi criteria analysis (thermodynamic, environmental, and safety) can achieve performance of 2.04. In the selection of refrigerants, refrigerants that are safe to use are still unable to achieve higher performance than dangerous refrigerants. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
spellingShingle Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
Paul Alfredo Purba, Rado
THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES
description Vapor compression-type heat pumps are increasingly in demand as heaters because they have higher performance than gas, oil, or electric heaters. Existing compression heat pumps are used to heat water to a temperature of less than 80?. Heating temperatures in various process industries usually require more than 100?. This heat pump uses a working fluid (refrigerant) which may harm the environment. For this reason, a system that can reach high temperatures with high performance and uses environmentally friendly refrigerants is needed. One development that can be made is the implementation of a cascade system. Therefore, this study analyzes the thermodynamics and environmental aspects of a three-stage heat pump system with temperatures up to 150ºC. This research begins with calculating the ideal Carnot refrigeration cycle for each stage. The study parameters include condensation temperature for each stage, global warming and ozone depletion potential, performance, and refrigerant safety class. Performance calculation of the vapor compression cycle uses the condensing temperature with the appropriate refrigerant for each stage. Refrigerant pairs obtained are then compared to each other based on performance, impact on the environment, and risk of use. The simulation shows the highest performance using methyl oleate, cyclopentane, and water can achieve performance of 2.07. The multi criteria analysis (thermodynamic, environmental, and safety) can achieve performance of 2.04. In the selection of refrigerants, refrigerants that are safe to use are still unable to achieve higher performance than dangerous refrigerants.
format Final Project
author Paul Alfredo Purba, Rado
author_facet Paul Alfredo Purba, Rado
author_sort Paul Alfredo Purba, Rado
title THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES
title_short THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES
title_full THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES
title_fullStr THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES
title_full_unstemmed THERMODYNAMIC ANALYSIS FOR PROSPECTIVE APPLICATION OF THREE-STAGE CASCADE HEAT PUMP AT HIGH TEMPERATURES
title_sort thermodynamic analysis for prospective application of three-stage cascade heat pump at high temperatures
url https://digilib.itb.ac.id/gdl/view/76267
_version_ 1822994794187587584