MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD
The Split-Hopkinson Shear Bar hat-shaped method is one of the developed techniques of the Split-Hopkinson Pressure Bar for determining the characteristic of material when subjected to shear load with a high strain rate. Misalignment is known to influence the accuracy of the final result of the Sp...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/77627 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:77627 |
---|---|
spelling |
id-itb.:776272023-09-12T09:11:26ZMISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD Ghani Harahap, Abdul Indonesia Final Project Split-Hopkinson Shear Bar, finite element, misalignment, shear stress-strain curve INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/77627 The Split-Hopkinson Shear Bar hat-shaped method is one of the developed techniques of the Split-Hopkinson Pressure Bar for determining the characteristic of material when subjected to shear load with a high strain rate. Misalignment is known to influence the accuracy of the final result of the Split-Hopkinson Pressure Bar. Therefore, this research is conducted to determine the misalignment effect in the Split-Hopkison Shear Bar hat-shaped method. In this research, finite element simulation will be conducted with Abaqus software. While Autodesk Inventor will be used for modeling component geometry. A convergence test will be conducted to determine the effect of element size on the accuracy and computational cost. Finite element modeling will be validated by comparing the stress-strain curve from the simulation to the theoretical and experiment. Six cases of misalignment were simulated to determine each case’s characteristic. The shear stress-strain curve shows that fluctuation tends to be higher when the output bar is misaligned than the input bar. The higher the misalignment in the output bar, the higher the fluctuation that results in a stress-strain curve. Hence, to get the more accurate testing result, support should have an offset tolerance of 1 mm, uneven height should be 0,55 mm per 1000 mm, the angle of impact face and specimen should be 0,03°, bar straightness should be 0,25 mm per 1000 mm, cone and dome impact faces should have an angle of 0,125° and 0,25°, respectively. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The Split-Hopkinson Shear Bar hat-shaped method is one of the developed techniques
of the Split-Hopkinson Pressure Bar for determining the characteristic of material when
subjected to shear load with a high strain rate. Misalignment is known to influence the
accuracy of the final result of the Split-Hopkinson Pressure Bar. Therefore, this research is
conducted to determine the misalignment effect in the Split-Hopkison Shear Bar hat-shaped
method.
In this research, finite element simulation will be conducted with Abaqus software.
While Autodesk Inventor will be used for modeling component geometry. A convergence
test will be conducted to determine the effect of element size on the accuracy and
computational cost. Finite element modeling will be validated by comparing the stress-strain
curve from the simulation to the theoretical and experiment.
Six cases of misalignment were simulated to determine each case’s characteristic. The
shear stress-strain curve shows that fluctuation tends to be higher when the output bar is
misaligned than the input bar. The higher the misalignment in the output bar, the higher the
fluctuation that results in a stress-strain curve. Hence, to get the more accurate testing result,
support should have an offset tolerance of 1 mm, uneven height should be 0,55 mm per 1000
mm, the angle of impact face and specimen should be 0,03°, bar straightness should be 0,25
mm per 1000 mm, cone and dome impact faces should have an angle of 0,125° and 0,25°,
respectively.
|
format |
Final Project |
author |
Ghani Harahap, Abdul |
spellingShingle |
Ghani Harahap, Abdul MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD |
author_facet |
Ghani Harahap, Abdul |
author_sort |
Ghani Harahap, Abdul |
title |
MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD |
title_short |
MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD |
title_full |
MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD |
title_fullStr |
MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD |
title_full_unstemmed |
MISALIGNMENT EFFECT ON TEST RESULTS OF THE SPLIT-HOPKINSON SHEAR BAR HAT-SHAPED METHOD |
title_sort |
misalignment effect on test results of the split-hopkinson shear bar hat-shaped method |
url |
https://digilib.itb.ac.id/gdl/view/77627 |
_version_ |
1822008327689732096 |