DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE

Energy consumption of air conditioning system can be the largest in a building. Energy efficient air conditioning methods are already studied and developed, but its application in Indonesia is not yet common. One of the methods that are already commonly used in other countries is hydronic radiant pa...

Full description

Saved in:
Bibliographic Details
Main Author: Mandiri, Mande
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/78511
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:78511
spelling id-itb.:785112023-10-12T08:54:43ZDESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE Mandiri, Mande Indonesia Final Project radiant panels, thermal comfort, air conditioning, energy efficient, simulation INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/78511 Energy consumption of air conditioning system can be the largest in a building. Energy efficient air conditioning methods are already studied and developed, but its application in Indonesia is not yet common. One of the methods that are already commonly used in other countries is hydronic radiant panels. Based on that background, this final project tries to apply hydronic radiant panels to FTMD ITB Coworking Space. The main literature used on this project to design the radiant panels are ASHRAE HVAC Systems and Equipments (2016) and ASHRAE Standard 55-2013: Thermal Environmental Conditions for Human Occupancy. Simulation with ANSYS Fluent is done to prove that the radiant panel formulations from ASHRAE is applicable in this context, and to get more precise parameters specific to this project. Then, simple simulation is done with EnergyPlus (with OpenStudio as its graphical user interface) to determine the thermal comfort of radiant panel system. Based on the design and simulation process, it is shown that the design formulations from ASHRAE can be a good reference (with error of 7,45%) and radiant panels can satisfy ASHRAE’s thermal comfort standard. Compared to split unit AC, an energy saving of 33,09% can be achieved, however it needs a chiller with high COP (to break even with split unit AC’s power consumption, a chiller with COP of higher than 3,486 is needed). The chiller should be located near the panels, and insulation for the chilled water pipe between the chiller and the panels to minimize heat loss to environment. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Energy consumption of air conditioning system can be the largest in a building. Energy efficient air conditioning methods are already studied and developed, but its application in Indonesia is not yet common. One of the methods that are already commonly used in other countries is hydronic radiant panels. Based on that background, this final project tries to apply hydronic radiant panels to FTMD ITB Coworking Space. The main literature used on this project to design the radiant panels are ASHRAE HVAC Systems and Equipments (2016) and ASHRAE Standard 55-2013: Thermal Environmental Conditions for Human Occupancy. Simulation with ANSYS Fluent is done to prove that the radiant panel formulations from ASHRAE is applicable in this context, and to get more precise parameters specific to this project. Then, simple simulation is done with EnergyPlus (with OpenStudio as its graphical user interface) to determine the thermal comfort of radiant panel system. Based on the design and simulation process, it is shown that the design formulations from ASHRAE can be a good reference (with error of 7,45%) and radiant panels can satisfy ASHRAE’s thermal comfort standard. Compared to split unit AC, an energy saving of 33,09% can be achieved, however it needs a chiller with high COP (to break even with split unit AC’s power consumption, a chiller with COP of higher than 3,486 is needed). The chiller should be located near the panels, and insulation for the chilled water pipe between the chiller and the panels to minimize heat loss to environment.
format Final Project
author Mandiri, Mande
spellingShingle Mandiri, Mande
DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE
author_facet Mandiri, Mande
author_sort Mandiri, Mande
title DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE
title_short DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE
title_full DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE
title_fullStr DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE
title_full_unstemmed DESIGN AND SIMULATION OF AIR CONDITIONING SYSTEM WITH HYDRONIC RADIANT PANELS IN FTMD ITB COWORKING SPACE
title_sort design and simulation of air conditioning system with hydronic radiant panels in ftmd itb coworking space
url https://digilib.itb.ac.id/gdl/view/78511
_version_ 1822995791076130816