STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG

Mixed Use Building Deli Serdang functions as a shopping center, office, and apartment. Mixed use building is made to maximize the function of the building while minimizing the space requirement and mobility of its occupants. This building consists of basements, podiums, office tower, and apartmen...

Full description

Saved in:
Bibliographic Details
Main Author: Louis Gunawan, Brandon
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/79254
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:79254
spelling id-itb.:792542023-12-18T13:42:08ZSTRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG Louis Gunawan, Brandon Teknik sipil Indonesia Final Project mixed use building, earthquake resistance, linear dynamic, response spectrum, structural system, dual system, special moment resisting frame, special structural wall INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/79254 Mixed Use Building Deli Serdang functions as a shopping center, office, and apartment. Mixed use building is made to maximize the function of the building while minimizing the space requirement and mobility of its occupants. This building consists of basements, podiums, office tower, and apartment tower. Structural design of Mixed-Use Building in Deli Serdang consists of reinforced concrete structural elements, such as RC beam, RC column, RC slab, and RC shear wall. These structural elements are designed according to SNI 2847:2019. The design loads for this building are determined according to SNI 1727:2020 and ASCE 7- 16. Mixed-Use Building in Deli Serdang will also be designed for earthquake resistance according to SNI 1726:2019. The earthquake resistance parameters checked for Mixed-Use Building in Deli Serdang consists of structure fundamental period, equivalent lateral force, inter story drifts, P-Delta effect, dual system requirement, horizontal irregularity, vertical irregularity, and redundancy factor. These parameters are checked according to SNI 1726:2019. The reinforcement for structural elements is designed according to the principle of design for capacity using the LRFD method. Structural loads will be amplified by an amplification factor, whilst the structural element’s capacity will be reduced by a reduction factor according to the designed capacity (axial, flexure, shear, torsion). The structural system chosen for the building is a dual system, combining the Special Moment Resisting Frame (SMRF) and the Special Structural Wall (SSW). Structural modeling and analysis are done using CSI ETABS to execute the one step, linear dynamic response spectrum analysis. All reinforcement design for RC beams and transversal reinforcement for columns are designed manually, longitudinal reinforcement for slabs are designed using CSI SAFE, and the longitudinal reinforcement for columns and shear walls are designed using spColumn. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
Louis Gunawan, Brandon
STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG
description Mixed Use Building Deli Serdang functions as a shopping center, office, and apartment. Mixed use building is made to maximize the function of the building while minimizing the space requirement and mobility of its occupants. This building consists of basements, podiums, office tower, and apartment tower. Structural design of Mixed-Use Building in Deli Serdang consists of reinforced concrete structural elements, such as RC beam, RC column, RC slab, and RC shear wall. These structural elements are designed according to SNI 2847:2019. The design loads for this building are determined according to SNI 1727:2020 and ASCE 7- 16. Mixed-Use Building in Deli Serdang will also be designed for earthquake resistance according to SNI 1726:2019. The earthquake resistance parameters checked for Mixed-Use Building in Deli Serdang consists of structure fundamental period, equivalent lateral force, inter story drifts, P-Delta effect, dual system requirement, horizontal irregularity, vertical irregularity, and redundancy factor. These parameters are checked according to SNI 1726:2019. The reinforcement for structural elements is designed according to the principle of design for capacity using the LRFD method. Structural loads will be amplified by an amplification factor, whilst the structural element’s capacity will be reduced by a reduction factor according to the designed capacity (axial, flexure, shear, torsion). The structural system chosen for the building is a dual system, combining the Special Moment Resisting Frame (SMRF) and the Special Structural Wall (SSW). Structural modeling and analysis are done using CSI ETABS to execute the one step, linear dynamic response spectrum analysis. All reinforcement design for RC beams and transversal reinforcement for columns are designed manually, longitudinal reinforcement for slabs are designed using CSI SAFE, and the longitudinal reinforcement for columns and shear walls are designed using spColumn.
format Final Project
author Louis Gunawan, Brandon
author_facet Louis Gunawan, Brandon
author_sort Louis Gunawan, Brandon
title STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG
title_short STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG
title_full STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG
title_fullStr STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG
title_full_unstemmed STRUCTURAL DESIGN OF MIXED-USE BUILDING IN DELI SERDANG
title_sort structural design of mixed-use building in deli serdang
url https://digilib.itb.ac.id/gdl/view/79254
_version_ 1822008831221170176