STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING

Indonesia is a very earthquake-prone country. This is dangerous especially for critical structures that must operate after an earthquake. The use of seismic isolation is one of the many efforts to mitigate the damage due to earthquakes, in which the isolated structures are expected to undergo very m...

Full description

Saved in:
Bibliographic Details
Main Author: Samuel, Jeff
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/79480
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:79480
spelling id-itb.:794802024-01-05T15:10:47ZSTUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING Samuel, Jeff Indonesia Theses Base Isolation, Story Isolation, Lead Rubber Bearing, Nonlinear Time History Anlysis, Earthquake-Resistant Concrete Structure, Basement INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/79480 Indonesia is a very earthquake-prone country. This is dangerous especially for critical structures that must operate after an earthquake. The use of seismic isolation is one of the many efforts to mitigate the damage due to earthquakes, in which the isolated structures are expected to undergo very minimum damage and can operate after big earthquakes. Seismic isolation is one of the passive control systems in the form of horizontally flexible but vertically stiff element that can “isolate” building structures above it, dissipate earthquake energy, and concentrate the deformation due to earthquake mostly on the seismic isolation system, whereby the superstructure above it undergoes minimum deformation and a reduction of earthquake force. At first, seismic isolation was developed to be places at base (base isolation system). As time goes by, an idea surfaces to put the seismic isolation on another story of the building, which is called the story isolation system. This system can enhance the seismic performance of the structure above and below the isolation system. But its dynamic behaviour is more complex compared to the base isolation system. This study conducts a comparation in design and structrual response of a low rise reinforced concrete hospital, consisting of a 2-story basement and 5-story upper structure, equipped with a Lead Rubber Bearing (LRB) isolation system. Three buildings are modeled, each with a different isolation plane. In the first model, isolation is at base (below the basement). In the second model, isolation is below the upper structure (between the basement and the upper structure). In the third model, isolation is located at the top of the upper structure (the fifth floor). Structural response is obtained by nonlinear time history analysis using seven pairs spectrally matched ground motions to each model. Supertructure is designed to behave elastically and nonlienar behaviour is expected only at the isolation system. Structural design is assessed by the LRB specification and reinforcement of seismic-resisting system. Structural response is assessed from the mode shape, base shear, roof acceleration, interstory drift, and energy dissipation of the LRB. It is found that placing the isolation system between the basement and the upperstructure gives the most optimum design and response, compared to the other two models. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Indonesia is a very earthquake-prone country. This is dangerous especially for critical structures that must operate after an earthquake. The use of seismic isolation is one of the many efforts to mitigate the damage due to earthquakes, in which the isolated structures are expected to undergo very minimum damage and can operate after big earthquakes. Seismic isolation is one of the passive control systems in the form of horizontally flexible but vertically stiff element that can “isolate” building structures above it, dissipate earthquake energy, and concentrate the deformation due to earthquake mostly on the seismic isolation system, whereby the superstructure above it undergoes minimum deformation and a reduction of earthquake force. At first, seismic isolation was developed to be places at base (base isolation system). As time goes by, an idea surfaces to put the seismic isolation on another story of the building, which is called the story isolation system. This system can enhance the seismic performance of the structure above and below the isolation system. But its dynamic behaviour is more complex compared to the base isolation system. This study conducts a comparation in design and structrual response of a low rise reinforced concrete hospital, consisting of a 2-story basement and 5-story upper structure, equipped with a Lead Rubber Bearing (LRB) isolation system. Three buildings are modeled, each with a different isolation plane. In the first model, isolation is at base (below the basement). In the second model, isolation is below the upper structure (between the basement and the upper structure). In the third model, isolation is located at the top of the upper structure (the fifth floor). Structural response is obtained by nonlinear time history analysis using seven pairs spectrally matched ground motions to each model. Supertructure is designed to behave elastically and nonlienar behaviour is expected only at the isolation system. Structural design is assessed by the LRB specification and reinforcement of seismic-resisting system. Structural response is assessed from the mode shape, base shear, roof acceleration, interstory drift, and energy dissipation of the LRB. It is found that placing the isolation system between the basement and the upperstructure gives the most optimum design and response, compared to the other two models.
format Theses
author Samuel, Jeff
spellingShingle Samuel, Jeff
STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING
author_facet Samuel, Jeff
author_sort Samuel, Jeff
title STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING
title_short STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING
title_full STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING
title_fullStr STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING
title_full_unstemmed STUDY ON DESIGN AND STRUCTURAL RESPONSE COMPARISON OF ABUILDING STRUCTURE WITH BASEMENT WITH LEAD RUBBER BEARING SEISMICISOLATION LOCATED AT BASE AND AT STORY OF THE BUILDING
title_sort study on design and structural response comparison of abuilding structure with basement with lead rubber bearing seismicisolation located at base and at story of the building
url https://digilib.itb.ac.id/gdl/view/79480
_version_ 1822996300692455424