DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS

The demand for decarbonization and the transition to new renewable energy sources are increasing the future demand for Photovoltaic (PV) to generate solar energy. With the rising trend in PV demand, discussions about failures in the Photovoltaic Solar Power System (PLTS) have become necessary. Undet...

Full description

Saved in:
Bibliographic Details
Main Author: Jauhar Sulaiman, Fakhri
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/79869
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:79869
spelling id-itb.:798692024-01-16T12:51:23ZDETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS Jauhar Sulaiman, Fakhri Indonesia Final Project enewable energy, photovoltaic fault, partial shading, machine learning, deep neural network INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/79869 The demand for decarbonization and the transition to new renewable energy sources are increasing the future demand for Photovoltaic (PV) to generate solar energy. With the rising trend in PV demand, discussions about failures in the Photovoltaic Solar Power System (PLTS) have become necessary. Undetected failures for an extended period have the potential to significantly reduce electricity production. Therefore, it is crucial to develop methods capable of detecting and diagnosing failures that occur in the PLTS. Each type of failure in the PLTS system results in differences in the shapes of the I-V and P-V curves. These differences enable the reading and detection of a specific type of failure by observing and analyzing the I-V and P-V curve shapes over a specific time span. A failure detection system for the PLTS will be developed using the Deep Neural Network (DNN) method with the main variables being the I-V and P-V curves. The focus of the detected failures will be on partial shading due to its frequent occurrence and ease of engineering and variation. Partial shading is applied by covering PV modules in the PLTS system at the ITB CAS Building with a carpet. Various amounts of shading are applied, ranging from 1 to 10 covered PV modules. I-V and P-V curve data are modeled using the DNN algorithm and then compared with modeling results using the Support Vector Machine (SVM) algorithm. The DNN training accuracy is 83.67%, while the SVM training accuracy is 63.89%. For validation accuracy, the DNN machine learning has a validation accuracy of 81.65%, while SVM has a validation accuracy of 64.69%. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The demand for decarbonization and the transition to new renewable energy sources are increasing the future demand for Photovoltaic (PV) to generate solar energy. With the rising trend in PV demand, discussions about failures in the Photovoltaic Solar Power System (PLTS) have become necessary. Undetected failures for an extended period have the potential to significantly reduce electricity production. Therefore, it is crucial to develop methods capable of detecting and diagnosing failures that occur in the PLTS. Each type of failure in the PLTS system results in differences in the shapes of the I-V and P-V curves. These differences enable the reading and detection of a specific type of failure by observing and analyzing the I-V and P-V curve shapes over a specific time span. A failure detection system for the PLTS will be developed using the Deep Neural Network (DNN) method with the main variables being the I-V and P-V curves. The focus of the detected failures will be on partial shading due to its frequent occurrence and ease of engineering and variation. Partial shading is applied by covering PV modules in the PLTS system at the ITB CAS Building with a carpet. Various amounts of shading are applied, ranging from 1 to 10 covered PV modules. I-V and P-V curve data are modeled using the DNN algorithm and then compared with modeling results using the Support Vector Machine (SVM) algorithm. The DNN training accuracy is 83.67%, while the SVM training accuracy is 63.89%. For validation accuracy, the DNN machine learning has a validation accuracy of 81.65%, while SVM has a validation accuracy of 64.69%.
format Final Project
author Jauhar Sulaiman, Fakhri
spellingShingle Jauhar Sulaiman, Fakhri
DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS
author_facet Jauhar Sulaiman, Fakhri
author_sort Jauhar Sulaiman, Fakhri
title DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS
title_short DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS
title_full DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS
title_fullStr DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS
title_full_unstemmed DETECTION OF SOLAR POWER PLANT SYSTEM FAULTS USING DEEP NEURAL NETWORK BASED ON I-V AND P-V CURVE CHARACTERISTICS
title_sort detection of solar power plant system faults using deep neural network based on i-v and p-v curve characteristics
url https://digilib.itb.ac.id/gdl/view/79869
_version_ 1822996569508544512