VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)

Cyanide is a toxic chemical that is very high. Risks associated with the use of cyanide is the exposure of workers by hydrogen cyanide gas. When contaminants are released into the environment are many factors that influence such as transport, accumulation, transformation, and degradation. Models try...

Full description

Saved in:
Bibliographic Details
Main Author: Rakhmawati, Ina
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/80691
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:80691
spelling id-itb.:806912024-02-27T12:44:59ZVALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK) Rakhmawati, Ina Hukum perdata Indonesia Theses Cyanidation, Hydrogen cyanide, Fugacity model,Linear regression, Uncertainties INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/80691 Cyanide is a toxic chemical that is very high. Risks associated with the use of cyanide is the exposure of workers by hydrogen cyanide gas. When contaminants are released into the environment are many factors that influence such as transport, accumulation, transformation, and degradation. Models trying to predict the partition fugasitas chemicals in the environment. The role of model calculations fugasitas as a tool that will receive the available input data, process, and provide relevant data output. Predictions of this model may not be very accurate, but the model can be consistent, repeatable, transparent, and can be validated to some extent by comparing the predictions of the model with direct observations in the field. The model used to validate the measurement of cyanide vapor is fugasitas model level I. Excess of fugasitas model calculation is used to compare differences in the level of contaminants in different environmental media and organisms. The research was conducted at PT. Antam tbk. The study was conducted with cyanide vapor measurement results validate the model fugasitas level 1. The results in the can that model fugasitas level 1 is more consistent than cyanide vapor measurements at the plant I and Process Plant II with a value of R2 results of linear regression analysis was 96% that the model fugasitas reach equilibrium with closed system, equilibrium, dan steady state asumsition results of research whereas the measurements results have not yet reached equilibrium with the uncertainty of measurements of calibration, instrumentation, and sampling and uncertainty of model not found Henry’slaw constanta in literature at 400 degrees text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Hukum perdata
spellingShingle Hukum perdata
Rakhmawati, Ina
VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)
description Cyanide is a toxic chemical that is very high. Risks associated with the use of cyanide is the exposure of workers by hydrogen cyanide gas. When contaminants are released into the environment are many factors that influence such as transport, accumulation, transformation, and degradation. Models trying to predict the partition fugasitas chemicals in the environment. The role of model calculations fugasitas as a tool that will receive the available input data, process, and provide relevant data output. Predictions of this model may not be very accurate, but the model can be consistent, repeatable, transparent, and can be validated to some extent by comparing the predictions of the model with direct observations in the field. The model used to validate the measurement of cyanide vapor is fugasitas model level I. Excess of fugasitas model calculation is used to compare differences in the level of contaminants in different environmental media and organisms. The research was conducted at PT. Antam tbk. The study was conducted with cyanide vapor measurement results validate the model fugasitas level 1. The results in the can that model fugasitas level 1 is more consistent than cyanide vapor measurements at the plant I and Process Plant II with a value of R2 results of linear regression analysis was 96% that the model fugasitas reach equilibrium with closed system, equilibrium, dan steady state asumsition results of research whereas the measurements results have not yet reached equilibrium with the uncertainty of measurements of calibration, instrumentation, and sampling and uncertainty of model not found Henry’slaw constanta in literature at 400 degrees
format Theses
author Rakhmawati, Ina
author_facet Rakhmawati, Ina
author_sort Rakhmawati, Ina
title VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)
title_short VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)
title_full VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)
title_fullStr VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)
title_full_unstemmed VALIDATION ANALYSIS OF CYANIDE VAPOR MEASUREMENTS WITH FUGACITY MODEL AT SEVERAL CONCENTRATIONS OF GOLD EXTRACTION BY CYANIDATION PROCESS (CASE STUDY: PT. ANTAM TBK)
title_sort validation analysis of cyanide vapor measurements with fugacity model at several concentrations of gold extraction by cyanidation process (case study: pt. antam tbk)
url https://digilib.itb.ac.id/gdl/view/80691
_version_ 1822996903433863168