DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS

In the medical field in Indonesia, training for vascular anastomosis procedures still does not closely resemble the actual conditions encountered during surgery. The best current training medium, namely cadavers, still cannot simulate conditions as realistically as possible due to factors such as...

Full description

Saved in:
Bibliographic Details
Main Author: Iftikhar Falakh, Fariz
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/82354
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:82354
spelling id-itb.:823542024-07-08T08:57:59ZDESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS Iftikhar Falakh, Fariz Indonesia Final Project anastomosis, training, flow rate, narrowing INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/82354 In the medical field in Indonesia, training for vascular anastomosis procedures still does not closely resemble the actual conditions encountered during surgery. The best current training medium, namely cadavers, still cannot simulate conditions as realistically as possible due to factors such as decomposition, among others. Additionally, the evaluation of anastomosis training procedures is often carried out using qualitative methods, which is not ideal as it relies on the subjectivity of the evaluator. Therefore, this project has developed a medical phantom training medium for vascular anastomosis that not only simulates conditions as closely as possible to the surgical environment but also provides quantitative evaluation of the training outcomes. This is done by flowing a blood substitute fluid with a flow rate that closely matches the flow in one of the human brain arteries, specifically the Middle Cerebral Artery Distal, where the flow ranges from 28-52 mL/min. Additionally, this medical phantom can evaluate the severity of narrowing that occurs in the blood vessel model due to the anastomosis suturing performed by the user. This is done by measuring the flow rate in the blood vessel model where the procedure is performed, as any narrowing will result in a decrease in flow rate compared to the flow when there is no narrowing. The sensor used to measure the blood flow can measure flows in the range of 0-52 mL/min.. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description In the medical field in Indonesia, training for vascular anastomosis procedures still does not closely resemble the actual conditions encountered during surgery. The best current training medium, namely cadavers, still cannot simulate conditions as realistically as possible due to factors such as decomposition, among others. Additionally, the evaluation of anastomosis training procedures is often carried out using qualitative methods, which is not ideal as it relies on the subjectivity of the evaluator. Therefore, this project has developed a medical phantom training medium for vascular anastomosis that not only simulates conditions as closely as possible to the surgical environment but also provides quantitative evaluation of the training outcomes. This is done by flowing a blood substitute fluid with a flow rate that closely matches the flow in one of the human brain arteries, specifically the Middle Cerebral Artery Distal, where the flow ranges from 28-52 mL/min. Additionally, this medical phantom can evaluate the severity of narrowing that occurs in the blood vessel model due to the anastomosis suturing performed by the user. This is done by measuring the flow rate in the blood vessel model where the procedure is performed, as any narrowing will result in a decrease in flow rate compared to the flow when there is no narrowing. The sensor used to measure the blood flow can measure flows in the range of 0-52 mL/min..
format Final Project
author Iftikhar Falakh, Fariz
spellingShingle Iftikhar Falakh, Fariz
DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS
author_facet Iftikhar Falakh, Fariz
author_sort Iftikhar Falakh, Fariz
title DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS
title_short DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS
title_full DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS
title_fullStr DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS
title_full_unstemmed DESIGN AND IMPLEMENTATION OF PUMP AND FLOW RATE MEASUREMENT SYSTEM IN MEDICAL PHANTOM FOR VASCULAR ANASTOMOSIS
title_sort design and implementation of pump and flow rate measurement system in medical phantom for vascular anastomosis
url https://digilib.itb.ac.id/gdl/view/82354
_version_ 1822997656427823104