STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA

The demand for multifunctional high-rise buildings in urban areas such as Central Jakarta is increasing, along with population growth and land constraints. Therefore, a mixed-use building that emphasizes the concept of one-stop-service property was developed. Oasis Central Sudirman is a super hig...

Full description

Saved in:
Bibliographic Details
Main Author: Hafizh Riyanto, Muhammad
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/82385
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:82385
spelling id-itb.:823852024-07-08T09:48:58ZSTRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA Hafizh Riyanto, Muhammad Teknik sipil Indonesia Final Project High-rise building, Mixed-used building, Response spectrum analysis, Linear time history analysis, Earthquake-resistant structure, Special moment-resisting frame system, Special coupled corewall, Outrigger, Belt truss, LRFD, Detailing. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/82385 The demand for multifunctional high-rise buildings in urban areas such as Central Jakarta is increasing, along with population growth and land constraints. Therefore, a mixed-use building that emphasizes the concept of one-stop-service property was developed. Oasis Central Sudirman is a super high-rise building project that consists of two towers. The first tower is a 74-story (325.05 m) mix-used building and the second tower is a 65-story (275.60 m) residential building. There are also 5 basement levels that are used as vehicle parking lots and are planned to accommodate up to 1600 vehicles. In the first tower, there is a podium structure that functions as a 5-story retail building that supports the tower structure. In this final project, the building to be designed is the first tower that is used as a mixused building. The material used in this building is a reinforced concrete. The main structural system used in this building is a special coupled corewall and a special moment-resisting frame system complemented by steel outriggers and belt truss is optimized to provide better seismic performance and optimal space efficiency. The structural modeling was performed in 3D using CSI ETABS software to analyze the response of the building to the loads. Floor plans were obtained from architectural drawings and structural element dimensions were determined based on SNI 2847:2019. The gravity and lateral loads used in the analysis refer to SNI 1727:2019, ASCE 7-16, SNI 1726:2019, and the Indonesian Earthquake Hazard Deaggregation Map. Earthquake load analysis is performed using response spectrum analiysis (RSA) and linear time history analysis (LTHA) based on SNI 1726:2019. The building structure shall include complete lateral and vertical force-resisting systems capable of providing adequate strength, stiffness, and energy dissipation capacity to withstand the design ground motions within the prescribed limits of deformation and strength demand. The structure is designed to satisfy the requirements of earthquake-resistant structures, which include modal participation mass ratio, equivalent lateral force, dual system requirements, horizontal and vertical irregularities of the structure, story drift, structural stability (P-Delta effects), and redundancy factor. The reinforcement design of structural elements based on the capacity design principle is performed based on the forces obtained from the LRFD load combination and refers to SNI 2847: 2019 / ACI 318-19. Design of beam reinforcement, including longitudinal, transverse and torsion bars. Design of column reinforcement, including longitudinal, confinement and transverse bars. Design of slab reinforcement, including longitudinal and transverse bars. Shear wall reinforcement design, including longitudinal, transverse and special boundary element (SBE) reinforcement. Design of coupling beam reinforcement, including diagonal, transverse and longitudinal bars. The strong column-weak beam (SCWB) and beam-column connections requirements were also checked to ensure that the structure remains ductile during the earthquake. In addition, the detailing of structural elements must be well designed to ensure that the structure will be able to dissipate earthquake energy through inelastic displacement mechanisms without collapsing. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
Hafizh Riyanto, Muhammad
STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA
description The demand for multifunctional high-rise buildings in urban areas such as Central Jakarta is increasing, along with population growth and land constraints. Therefore, a mixed-use building that emphasizes the concept of one-stop-service property was developed. Oasis Central Sudirman is a super high-rise building project that consists of two towers. The first tower is a 74-story (325.05 m) mix-used building and the second tower is a 65-story (275.60 m) residential building. There are also 5 basement levels that are used as vehicle parking lots and are planned to accommodate up to 1600 vehicles. In the first tower, there is a podium structure that functions as a 5-story retail building that supports the tower structure. In this final project, the building to be designed is the first tower that is used as a mixused building. The material used in this building is a reinforced concrete. The main structural system used in this building is a special coupled corewall and a special moment-resisting frame system complemented by steel outriggers and belt truss is optimized to provide better seismic performance and optimal space efficiency. The structural modeling was performed in 3D using CSI ETABS software to analyze the response of the building to the loads. Floor plans were obtained from architectural drawings and structural element dimensions were determined based on SNI 2847:2019. The gravity and lateral loads used in the analysis refer to SNI 1727:2019, ASCE 7-16, SNI 1726:2019, and the Indonesian Earthquake Hazard Deaggregation Map. Earthquake load analysis is performed using response spectrum analiysis (RSA) and linear time history analysis (LTHA) based on SNI 1726:2019. The building structure shall include complete lateral and vertical force-resisting systems capable of providing adequate strength, stiffness, and energy dissipation capacity to withstand the design ground motions within the prescribed limits of deformation and strength demand. The structure is designed to satisfy the requirements of earthquake-resistant structures, which include modal participation mass ratio, equivalent lateral force, dual system requirements, horizontal and vertical irregularities of the structure, story drift, structural stability (P-Delta effects), and redundancy factor. The reinforcement design of structural elements based on the capacity design principle is performed based on the forces obtained from the LRFD load combination and refers to SNI 2847: 2019 / ACI 318-19. Design of beam reinforcement, including longitudinal, transverse and torsion bars. Design of column reinforcement, including longitudinal, confinement and transverse bars. Design of slab reinforcement, including longitudinal and transverse bars. Shear wall reinforcement design, including longitudinal, transverse and special boundary element (SBE) reinforcement. Design of coupling beam reinforcement, including diagonal, transverse and longitudinal bars. The strong column-weak beam (SCWB) and beam-column connections requirements were also checked to ensure that the structure remains ductile during the earthquake. In addition, the detailing of structural elements must be well designed to ensure that the structure will be able to dissipate earthquake energy through inelastic displacement mechanisms without collapsing.
format Final Project
author Hafizh Riyanto, Muhammad
author_facet Hafizh Riyanto, Muhammad
author_sort Hafizh Riyanto, Muhammad
title STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA
title_short STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA
title_full STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA
title_fullStr STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA
title_full_unstemmed STRUCTURAL DESIGN OF AN EARTHQUAKE-RESISTANT 74-STORY MIXED-USE BUILDING WITH OUTRIGGER & BELT TRUSS SYSTEM IN CENTRAL JAKARTA
title_sort structural design of an earthquake-resistant 74-story mixed-use building with outrigger & belt truss system in central jakarta
url https://digilib.itb.ac.id/gdl/view/82385
_version_ 1822009757131603968